5.2.1.3.8 The Deck Statistics display

Figure 69: Deck Statistics Display shows the relation of good/bad produced wallboard sets

This sub-display is a very important one to have an overview of the current production quality. The
example above indicates a very bad production result, because the relation between good/bad board
sets is about 0.1 (10% good, 90% bad). This might be also an indication for an inaccurate recipe or
overall configuration. Herein the bad result was intentionally forced by a bad recipe configuration with
bad reference boards per deck.
Note: Just high quality reference board sets enable a good defect detection capability by the SW
algorithm. Especially the kiln deck temperature variance has to be taken into account, if the
variance between the decks is high. Please use individual reference board set per deck or adapt
the individual defect detection threshold temperature per deck.