Fluke TIP900 Operating Instructions Manual page 43

Wallboard temperature imaging & profiling system
Table of Contents

Advertisement

Type:
Note:
# of Board in Set:
Min. time Dropgate  Scanner:
Max. time Dropgate  Scanner:
Min. temp of the color range:
Max. temp of the color range:
Trigger Background-Temperature: The background temperature of the process. A new snapshot will
Trigger Start-Delta-Temperature:
Trigger-Stop-Delta-Temperature:
TIP900
-- General parameters --
The specific type identifier for similar recipes, which differ in minor
items. The type name is very important to keep a proper data
archive structure alive. There is for each type name a specific folder
or database table created, where the assigned images will be
stored.
Additional textual description and information for the specific recipe
The count of boards per deck. Each board of every deck needs a
shape to be defined in the recipe editor.
The default minimum time between a dropgate signal set and the
scanning start of a board. To avoid configuration errors, "Min. time
Dropgate → Scanner" has to be smaller than "Max. time Dropgate
→ Scanner" and the distance between them should be at least 1
second. This parameter will be overridden by the corresponding
recipe parameter.
The default maximum time between a dropgate signal set and the
scanning start of a board. To avoid configuration errors, "Min. time
Dropgate → Scanner" has to be smaller than "Max. time Dropgate
→ Scanner" and the distance between them should be at least 1
second. This parameter will be overridden by the corresponding
recipe parameter.
The minimum temperature of the color range. Used in the history,
the recipe editor and in the LogViewer. To avoid recipe errors "Min.
temp of the color range" must be smaller than "Max. temp of the
color range" and the distance between them should be at least 10
degrees.
The maximum temperature of the color range. Used in the history,
the recipe editor and in the LogViewer. To avoid recipe errors "Min.
temp of the color range" must be smaller than "Max. temp of the
color range" and the distance between them should be at least 10
degrees.
be started when the scanner measures a temperature above
"Trigger
Background-Temperature"
Temperature". The snapshot will be stopped when the scanner
measures a temperature below "Trigger Background-Temperature"
+ "Trigger Stop-Delta-Temperature".
A new snapshot will be started when the scanner measures a
temperature above "Trigger Background-Temperature" + "Trigger
Start-Delta-Temperature".
A snapshot will be stopped when the scanner measures a
temperature below "Trigger Background-Temperature" + "Trigger
Stop-Delta-Temperature".