Fluke TIP900 Operating Instructions Manual page 51

Wallboard temperature imaging & profiling system
Table of Contents

Advertisement

Logic Level:
Application Watchdog:
Output Hold Time:
Operator can disable the reject signal:
-- Temperature Compensation: Temperature Compensation Settings MI3--
IP address:
Port:
Enable Temp. Compensation:
Temperature Delta Threshold:
TComp Sensor Zone:
Assigned Sensor Deck:
Emissivity:
TIP900
-- Inputs/Outputs: IO-Settings --
Sets the type of logic level "Active-High" or "Active-Low".
Assigns the output of the application watchdog. The
application watchdog applies to communication errors of the
scanner, the temperature compensation (Mi3) and a crash of
the TIP900 application. Selection criteria are "Relay2" or
"Digital Output 2".
The reset time after a watchdog triggered event (Output)
releases the hold state. The application watchdog remains
unaffected.
-- Inputs/Outputs: IO-Permissions --
The operator is allowed to disable the reject signal. If enabled,
an operator can disable the reject signal. The corresponding
reject output signal will then not be triggered.
IP address of the temperature compensation. The MI3 box
default address is "192.168.42.130".
The port to be used for communication with the temperature
compensation (MI3 box) in the network. The default port
number is "6363".
-- Temperature Compensation: Parameter--
Setting to enable or disable the temperature compensation.
Possible selection is Yes/No.
The temperature delta threshold is the delta temperature to
the ambient temperature of the compensation sensor to start
the recording of temperature compensation values.
The zone where the temperature compensation sensor looks
at in the board map. A board map is divided into four areas.
Counting direction is from left to right. Zone 1 is most left in
the board map. Zone 4 is most right in the board map.
This is the deck where the compensation sensor is mounted
and measures the temperature.
The emissivity of the material to measure. The right value has
to be determined regarding the background (black paddle
surface of counter telescope arm).
Rev. E1 Feb 2016
Operation
51

Advertisement

Table of Contents