The Map Data Selector In The Menu Bar; The Dryer Profile Selector In The Menu Bar; Figure 96: Tip900 - Log Viewer Display Of Full Map Data; Figure 97: Tip900 - Log Viewer Display Of Boards Only Map Data - Fluke TIP900 Operating Instructions Manual

Wallboard temperature imaging & profiling system
Table of Contents

Advertisement

Operation

5.3.1.1.4 The Map Data selector in the menu bar

Figure 96: TIP900 – Log Viewer display of Full Map Data
The selection of "Full" map data calculates and displays the maximum, the average and minimum
temperature values per scanned board map set, whereas "Full" takes also the non-board pixel into
account for the calculation. The lower blue minimum temperature curve in Figure 96 represents more or
less the board map background temperatures (black area around the boards), whereas the minimum
temperature is close to the lowest acquired value (e.g. floor ambient temperature).
Figure 97: TIP900 – Log Viewer display of Boards Only Map Data
The selection of "Boards Only" map data calculates and displays the maximum, the average and
minimum temperature values per scanned board map set, whereas "Boards Only" takes just the valid
board pixel into account for the calculation. This display type selection represents the real temperature
values of produced wallboard sets.

5.3.1.1.5 The Dryer Profile selector in the menu bar

Figure 98: TIP900 – Log Viewer display of the Dryer Profile
88
TIP900
Rev. E1 Feb 2016

Advertisement

Table of Contents
loading

Table of Contents