(2) Click Display switch in the menu to highlight it.
(3) Click the numeric value in the Offset Menu to display the setup box of
vertical position; it is available to directly input the value or turn the
general knob to set the required vertical position.
Application of Vertical Displacement Knob and Vertical Gear Knob
1. Vertical Displacement knob to adjust the vertical displacement of
corresponding channel waveform.
The resolution of this control key changes with the vertical gear.
2. Vertical Gear knob to adjust the vertical resolution of corresponding
channel waveform.
Determine the sensitivity of the vertical gear by stepping in a 1-2-5 system
mode.
The vertical displacement and vertical channel information are shown in the
lower left of the screen, as shown in Figure 5-4.

How to set horizontal system

There are HOR key, Horizontal Displacement knob and Horizontal Gear
knob in the Horizontal System Control Area.
1.Horizontal Displacement knob: Adjust the horizontal displacement of
all channels (including the mathematical operation), whose resolution
changes with the time base.
2.Horizontal Gear knob: Set the horizontal scale factor for the main
window or amplified window.
3.HOR key: Open the horizontal setting box, which can be switched
between the normal mode and the waveform amplification mode. See
5.Use the Oscilloscope
Figure 5- 4:Vertical Information