LOG SENSE Command (4Dh) (continued)
TAPE ALERT LOG PARAMETERS
Bit
7
Byte
5n –1
(MSB)
to
5n
5n + 1
DU
5n + 2
5n + 3
Value of TapeAlert Flag (Flag is set when Bit 0 = 1; Bits 1 – 7 are Reserved)
Figure 5–25 Log Parameters Format for TapeAlert Page
Table 5–25 Log Parameter Field Descriptions for TapeAlert Page
Field Name
Parameter Code
Parameter Length
Value of Tape Alert Flag
For definitions of bits that make up the Control Byte (the byte "5n + 1" above), refer to
Section 5.8.3, Table 5-21.
6
5
Parameter Code ( n)
DS
TSD
Parameter Length (1)
Description
This field contains the Flag code. See Table 5-26 for the supported
Flags, level of severity, and the Flags' definitions.
This field is set to 1.
If Bit 0 is set to 1, indicates that TapeAlert has sensed a problem. See
Table 5-26 for the supported Flags and their definitions. If Bit 0 is 0,
the Flag is not set and no problem has been sensed.
Quantum DLT 8000 Tape System
4
3
ETC
TMC
SCSI Commands
2
1
Rsv'd
0
(LSB)
LP
5-57