LOG SENSE Command (4Dh) (continued)
LOG PARAMETERS
Bit
7
Byte
(MSB)
0 -1
2
DU
3
(MSB)
4 - n
Figure 5–23 Log Parameters Format for LAST n ERROR EVENTS LOG SENSE Page
Table 5–23 Log Parameters for LAST n ERROR EVENTS LOG SENSE Page Field
Field Name
Parameter Code
Hex ASCII String for Event n
For definitions of bits that make up the Control Byte (byte 2), refer to Section 5.8.3., Table 5-
21.
6
5
Parameter Code
DS
TSD
ETC
Parameter Length
Hex ASCII String for Event n
Descriptions
Description
Parameter Code values are assigned from 0 to 27, where 0 is the
oldest event stored and the highest Parameter Code returned is the
most recent event.
The text of the parameter includes a "Packet #" that is a value from 0
to 255. This internal number is assigned when the packet is written to
EEPROM. A value of 0 is normally the oldest packet, but packet
numbers can wrap around back to 0 after reaching 255. For a
description of the packet string, see Appendix B.