Closing Procedures - Taylor PH61 Operator's Manual

Heat treatment shake freezer
Hide thumbs Also See for PH61:
Table of Contents

Advertisement

Figure 6-65
1. If less than 1 fl. oz. (30 ml) is received, the pressure
must be increased. Loosen the lock nut. Using a flat
blade screwdriver, turn the adjusting screw
clockwise.
2. Recheck the syrup calibration. Tighten the lock nut
after the correct calibration is achieved.
3. If more than 1 fl. oz. (30 ml) is received, the pressure
must be decreased. Loosen the lock nut and turn the
adjusting screw counterclockwise to zero. Remove
the air line to the syrup tank to allow the pressure in
the tank to escape. Reconnect the air line. Adjust the
regulator to the new pressure setting and recheck the
syrup calibration. Tighten the lock nut.
4. Repeat the "Calibrating the Syrup Flow" and
"Adjusting the Syrup Pressure" for each additional
syrup line.
5. Remove the syrup sampler. Lightly lubricate the 
O-ring on each syrup line fitting. (See Figure 6-66.)
Figure 6-66
Operating Procedures
6. Attach the syrup lines to the freezer door. Insert the
syrup line fitting into the syrup port in the freezer
door. The flat side of the syrup line fitting must be
aligned with the pin in the syrup port. Rotate the
syrup line fitting upward to lock in place. 
(See Figure 6-67.)
Note: Whenever a particular syrup line is not used,
the syrup hole plug found in the spare parts kit must
be installed. Place the syrup hole plug O-ring into the
groove of the syrup hole plug and lubricate. Align the
flat portion of the syrup hole plug with the locking pin
in the open syrup port of the freezer door. Insert the
syrup hole plug and turn slightly to lock in place.
7. Clean the calibration cup and syrup sampler.
Note: This procedure must be performed weekly.

Closing Procedures

Important! This procedure must be completed every
14 days.
ALWAYS FOLLOW LOCAL HEALTH CODES.
To disassemble the PH61, the following items will be
needed:
Two pails for cleaning and sanitizing
Cleaning brushes (provided with freezer)
Cleaning solution
Sanitizing solution
Clean, sanitized towels
Parts trays
Model PH61
OPERATING PROCEDURES
Figure 6-67
6
6-17