SAFETY
If the supply cord is damaged, it must be
replaced by the manufacturer, service agent, or
a similarly qualified person to avoid a hazard.
Secure supply cord ground lead to machine in a
location where if the cord is pulled the main
power leads become taut before the ground
lead can break loose.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
distributor for service.
IMPORTANT! An equipotential grounding lug is
provided with this machine. Some countries require the
3
grounding lug to be properly attached to the rear of the
frame by the authorized installer. The installation location
is marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on both the removable panel and the
machine's frame.
WARNING! Avoid injury.
DO NOT allow untrained personnel to operate
this machine.
DO NOT put objects or fingers in the door spout.
DO NOT operate the machine unless all service
panels and access doors are fastened with
screws.
DO NOT remove the machine door or beater
assembly unless the control switches are in the
OFF position.
Failure to follow these instructions may result in severe
personal injury, especially to fingers or hands, from
hazardous moving parts.
WARNING! This machine has many sharp
edges that can cause severe injuries.
DO NOT put objects or fingers in the door
spout. This may contaminate the product and
cause severe personal injury from blade
contact.
USE EXTREME CAUTION when removing the
beater assembly. The scraper blades are very
sharp.
3-2
USE EXTREME CAUTION when handling the
cup/cone dispenser (if supplied with machine).
Two people are required to handle the cup/cone
dispenser. The appropriate type of protective
gloves must be worn and the mounting holes
must NOT be used to lift or hold the dispenser.
Failure to follow these instructions can result in personal
injury or damage to the machine.
WARNING! DO NOT attempt to draw product or
disassemble the machine during the Heat Treatment
cycle (if equipped). The product is hot and under extreme
pressure. Severe burns from hot product may result if this
instruction is not followed.
CAUTION! This machine must be placed on a
level surface. Extreme care should be taken when
moving for any reason. Two or more persons are
required to safely move this machine. Failure to comply
may result in personal injury or damage to the machine.
DANGER! Some consumers are highly allergic
to strawberries. In some severe cases, allergic reactions
to strawberries can cause death.
When blending natural strawberry products, make sure
excess product is removed from the pitcher to eliminate
product carryover.
WARNING! Only install this machine in a
location where its use and maintenance is restricted to
trained personnel. Failure to comply may result in
personal injury.
NOTICE! Cleaning and sanitizing schedules
are governed by your federal, state, or local regulatory
agencies and must be followed accordingly. Please refer
to the cleaning section of this manual for the proper
procedure to clean this machine.
Model PH61