Priming; Closing Procedures; Draining Product From The Freezing Cylinder - Taylor 390 Operator's Manual

Slush freezer
Hide thumbs Also See for 390:
Table of Contents

Advertisement

OPERATING PROCEDURES

Priming

Note: If your freezer is equipped with the Remote
Continuous Fill System, replace the following priming
instructions with the information on page 5-1.
1. With a pail beneath the door spout, move the draw
handle to the right. Fill the hopper with fresh slush
product and allow it to flow into the freezing cylinder.
This will force out any remaining sanitizing solution.
When full strength mix is flowing from the door spout,
move the draw handle to the left.
Important! Failure to remove all sanitizing solution
may result in damage to the freezing cylinder.
2. When the slush product has stopped bubbling down
into the freezing cylinder, install the feed tube in the
mix inlet hole.
3. Place the control switch in the AUTO position. To
begin refrigeration, raise the rod resting on top of the
valve handle pin.When the unit cycles off, the product
will be at serving viscosity.
4. Place the hopper cover into position.

Closing Procedures

To disassemble model 390, the following items will be
needed:
6
Two cleaning pails
Sanitized stainless steel rerun can with lid
Necessary brushes (provided with freezer)
Cleaner
Single-service towels
6-4
Draining Product from the Freezing
Cylinder
1. Place the control switch in the OFF position as far
ahead of cleaning time as possible. This will allow
frozen product to soften for easier cleaning.
2. Remove the hopper cover, gasket, and feed tube.
Take these parts to the sink for cleaning.
3. If local health codes permit the use of rerun, place
a sanitized, NSF-approved stainless steel rerun
container beneath the door spout. Place the control
switch in the WASH position and move the draw
handle to the right. When all the product stops
flowing from the door spout, move the draw handle to
the left and place the control switch in the OFF
position. Place a sanitized lid on the rerun container
and place it in the walk-in cooler.
Note: For additional information regarding the
proper use of rerun, see Troubleshooting Guide on
page 7-1.
Note: If local health codes do not permit the use of
rerun, the product must be discarded. Follow the
instructions in the previous step, except drain the
product into a pail and properly discard the mix.
ALWAYS FOLLOW LOCAL HEALTH CODES.