Faults (Qax913 Only); Fault Input Source - Siemens Synco living QAX913 Mounting And Commissioning

Hide thumbs Also See for Synco living QAX913:
Table of Contents

Advertisement

Meter 4
Meter connected to the 2nd pulse input of the 1st pulse
adapter AEW2.1 of the apartment.
Meter 5
Meter connected to the 1st pulse input of the 2nd pulse
adapter AEW2.1 of the apartment.
Meter 6
Meter connected to the 2nd pulse input of the 2nd pulse
adapter AEW2.1 of the apartment.
General
Meter connected to the 1st pulse input of the pulse adapter
meter 1
AEW2.1 with plug 121.
General
Meter connected to the 2nd pulse input of AEW2.1 with plug
meter 2
121 or to the 1st pulse input of AEW2.1 with plug 124.
General
Meter connected to the 1st pulse input of the pulse adapter
meter 3
AEW2.1 with plug 122.
General
Meter connected to the 2nd pulse input of AEW2.1 with plug
meter 4
122 or to the 1st pulse input of AEW2.1 with plug 125.
General
Meter connected to the 1st pulse input of the pulse adapter
meter 5
AEW2.1 with plug 123.
General
Meter connected to the 2nd pulse input of AEW2.1 with plug
123 or to the 1st pulse input of AEW2.1 with plug 126.
meter 6
Value "Meter 1" to "Meter 6" must be set for meters allocated to bill-
ing in the apartment.
For general meters, set value "General meter 1" to "General meter 6".
In addition, a setting value can be used only for a meter.

Faults (QAX913 only)

Fault input source

Specify the source of the fault input state for central apartment unit QAX913.
Main menu > Commissioning > Extra configuration > Faults
> Fault input X > Source:
---
Inactive – fault contact not available (factory setting).
• Fault contact connected to universal input B of an
Via RF
• Fault contact connected to external contact input of a
• Use water detector QFP910 as fault input.
• Fault status of an S-mode object is received via KNX TP1 *.
B (local)
Fault contact connected to universal input B of the central
apartment unit.
* Connection of the respective S-mode objects of the central apartment unit to the relevant S-mode de-
vices on KNX TP1 via commissioning tool (ETS).