Configure fault input/output (QAX913 only)

Fault inputs 1 – 8
The fault contact of an external component can be connected to an appropri-
ately defined fault input. Typical components are water detectors (e.g. defec-
tive water line), an alarm output of an intrusion alarm system, or a thermal
switch.
Activate a fault input by assigning the corresponding fault type.
Main menu > Commissioning > Basic configuration
> Faults > Fault input X:
---
Water leakage
Gas leakage
CO alarm
Panic
Emergency
Fault 1 – 3
Fault text, fault priority, fault release, fault status message delay and the nor-
mal position can be separately set for faults 1 – 3. For a description of the
relevant settings, see the Operating Instructions, section "Faults".
Only a fault message delay can be set for fault types water leak, gas
leak, and CO alarm.
Faults Panic and Emergency do not require settings.

Fault outputs 1 and 2

If system faults occur, they can be forwarded to an external component by
closing a fault output. See the related section on page 40.
You can select the fault priority and origin of fault for the relay to close. For a
description of these settings, see the Operating Instructions, section "Faults".
Specify if a fault output is used and how it should be controlled.
Main menu > Commissioning > Basic configuration
> Faults > Fault output X:
---
Via RF
Q1 (local)
Siemens
Building Technologies
Inactive – Fault input not required (factory setting).
Fault input signals a water leak.
Fault input signals a gas leak.
Fault input signals a CO alarm.
Fault input signals a panic alarm.
Fault input signals an emergency alarm.
User-defined fault 1 – 3.
Inactive – Fault output not needed (factory setting).
Relay output Qx of an RRV91... heating circuit control-
ler or RRV934 multi-controller used as a fault output.
Relay output Q1 of the central apartment unit used as
a fault output.
Synco™ living
Commissioning the system
37 / 134