Supervision (QAX913 only)
Supervision contact
Closing the related input terminal (e.g. via key switch) switches over the su-
pervision state from "Inactive" to "All monitored" or from "All monitored" to "In-
active".
Specify if an external supervision contact is used and from where the central
apartment unit receives its status.
Main menu > Commissioning > Basic configuration > Supervision
> Supervision contact:
---
Via RF/S-mode
B (local)
* Connection of the respective S-Mode objects of the central apartment unit to the relevant S-Mode de-
vices on KNX TP1 via commissioning tool (ETS).
Supervision state
This output shows the status of supervision (e.g. on key switch). The relay
output is closed when supervision state corresponds to "Partly monitored" or
"All monitored".
Specify if a relay should be used to issue the supervision state and how it is
controlled.
Main menu > Commissioning > Basic configuration > Supervision
> Supervision state:
---
Via RF/S-mode
Q1 (local)
* Connection of the respective S-Mode objects of the central apartment unit to the relevant S-Mode de-
vices on KNX TP1 via commissioning tool (ETS).
38 / 134
Siemens
Building Technologies
Inactive – no input terminal available
(factory setting).
• Supervision contact connected to universal input B
of an RRV91... heating circuit controller or univer-
sal input Xx of an RRV934 multi-controller.
• Supervision signal received through S-Mode ob-
ject via KNX TP1 *
Supervision contact connected to universal input B of
the central apartment unit.
Inactive – no supervision display (factory setting).
Supervision state issued via:
• Relay output Qx of an RRV91.. heating circuit con-
troller or RRV934 multi-controller.
• S-mode object on KNX TP1 *.
Supervision state issued via relay output Q1 of the
central apartment unit.
Synco™ living
Commissioning the system
CE1C2740en