a. If you are unable to get a response during a ping test, attempt to ping another compute node in
the enclosure to determine whether it is a connection problem or compute node problem.
b. Run a trace route to determine where the connection breaks down. Attempt to resolve a
connection issue with either the VPN or the point at which the connection breaks down.
4. Restart the compute node remotely through the management interface.
5. If the problem remains, verify that any new software has been installed and configured correctly.
6. Contact your place of purchase of the software or your software provider.
Server is unresponsive (POST failed and cannot start System Setup)
Configuration changes, such as added devices or adapter firmware updates, and firmware or application
code problems can cause the server to fail POST (the power-on self-test).
If this occurs, the server responds in either of the following ways:
• The server restarts automatically and attempts POST again.
• The server hangs, and you must manually restart the server for the server to attempt POST again.
After a specified number of consecutive attempts (automatic or manual), the server reverts to the default
UEFI configuration and starts System Setup so that you can make the necessary corrections to the
configuration and restart the server. If the server is unable to successfully complete POST with the default
configuration, there might be a problem with the system board (system board assembly).
You can specify the number of consecutive restart attempts in System Setup. Restart the server and press
the key according to the on-screen instructions to display the LXPM system setup interface. (For more
information, see the "Startup" section in the LXPM documentation compatible with your server at
sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_page.html
Recovery and RAS ➙ POST Attempts ➙ POST Attempts Limit. Available options are 3, 6, 9, and disable.
Voltage planar fault is displayed in the event log
Complete the following steps until the problem is solved.
1. Revert the system to the minimum configuration. See
required number of processors and DIMMs.
2. Restart the system.
• If the system restarts, add each of the removed items one at a time and restart the system each time
until the error occurs. Replace the item for which the error occurs.
• If the system does not restart, suspect the system board (system board assembly).
Unusual smell
Complete the following steps until the problem is solved.
1. An unusual smell might be coming from newly installed equipment.
2. If the problem remains, contact Lenovo Support.
Server seems to be running hot
Complete the following steps until the problem is solved.
Multiple compute nodes or chassis:
1. Make sure that the room temperature is within the specified range (see
2. Make sure that the fans are installed correctly.
3. Update the UEFI and XCC to the latest versions.
.) Then, click System Settings ➙