Using Analog Modulation (Option UNT)

Using an Internal Modulation Source

Using an Internal Modulation Source

1. Preset the signal generator.
2. Set the carrier (RF) frequency.
3. Set the RF amplitude.
4. Configure the modulation:
AM
a. Press AM
b. Set the AM type (Linear or Exponential):
to highlight desired type.
AM Type
c. Set the AM Mode (Normal or Deep).
Default is Deep. To select Normal enable
More to highlight desired type.
d. Set the AM Depth:
Default 0.01%
Range
0.01 to 100%
e. Set the rate:
More > Setup AM Source > AM Rate > value
> frequency unit
5. Turn on the modulation:
AM
AM Off On softkey to On
The appropriate modulation annunciator displays, indicating that you enabled modulation.
6. Turn on the RF output.
The RF output LED lights, indicating that the signal is transmitting from the RF output connector.
If the modulation does not seem to be working properly, refer to
on page
382.
See also
"Modulating the Carrier Signal" on page
78
a. Press FM/ΦM
b. Set the deviation:
FM Dev > value > frequency unit
c. Set the rate:
More > Setup FM Source > FM Rate >
value > frequency unit
AM Depth
> value
FM Off On softkey to On
FM
a. Press FM/ΦM > FM ΦM
b. Set the BW (normal or high):
c. Set the deviation:
d. Set the rate:
value > frequency unit
FM
ΦM Off On softkey to On
"No Modulation at the RF Output"
59.
Agilent X-Series Signal Generators User's Guide
ΦM
FM ΦM to highlight desired type
ΦM Dev > value > pi rad
More > Setup ΦM Source > ΦM Rate >
ΦM