Viewing And Modifying Header Information - Agilent Technologies X Series User Manual

Signal generators
Hide thumbs Also See for X Series:
Table of Contents

Advertisement

Table 8-1 File Header Entries (Continued)
RF Blank Routing
Mod Attenuation
BB Freq Offset
AWGN: State
AWGN: C/N Ratio
AWGN: Carrier BW
AWGN: Noise BW
AWGN: Carrier RMS
Phase Noise State
Phase Noise F1
Phase Noise F2
Phase Noise Lmid
Modulation Filter
Over–Range Protect
Unique Waveform Id
License Required
Can be Read Out

Viewing and Modifying Header Information

The following example uses the factory–supplied waveform file RAMP_TEST_WFM.
1. From BBG media, select the waveform RAMP_TEST_WFM:
a. Press Mode > Dual ARB > Select Waveform.
b. In the Segment On column, highlight the waveform RAMP_TEST_WFM.
c. Press Select Waveform.
2. Open the Header Utilities menu:
Press More > Header Utilities
The
Figure 8- 5
shows the default file header for the factory–supplied waveform RAMP_TEST_WFM.
The Header Field column lists the file header parameters; use the Page Down key to see them all.
The Saved Header Settings column shows that most of the settings are Unspecified.
Unspecified means that there is no setting saved for that particular parameter.
Agilent X-Series Signal Generators User's Guide
Which marker, if any, implements the RF blanking function (described on
marker signal is low. RF blanking also uses ALC hold. There is no need to select the ALC Hold
Routing for the same marker when you are using the RF Blank Routing function. When the marker
signal goes high, RF blanking discontinues.
The I/Q modulator attenuation setting (set in the Arb Setup menu shown in
page
147).
The baseband frequency offset, in Hz (see
Indicated whether real–time noise is on (1) or off (0) (see
Carrier to noise ration, in dB (see
Bandwidth over which the noise power is integrated, in Hz (see
Bandwidth of the noise, in Hz (see
The carrier RMS across the carrier bandwidth (see
Indicated whether phase noise is on (1) or off (0) (see
The start frequency for the level mid–frequency characteristics (see
The end frequency for the level mid–frequency characteristics (see
The amplitude for the level mid–frequency characteristics (see
The real- time modulation filter type selected (see
Indicated whether DAC Over–Range Protection is on (1) or off (0) (see
0 = no Id; once an Id is assigned, it cannot be changed.
Indicates whether a license is required to play the waveform. See also:
Licenses" on page 40
Indicates whether the waveform can be queried through SCPI or FTP.
Basic Digital Operation (Option 653/655/656/657)
Saving a Waveform's Settings & Parameters
page
200).
page
page
250).
page
250).
page
250).
page
310).
page
224).
page
172) when the
Figure 8- 1 on
245).
page
250).
page
310).
page
310).
page
310).
page
314).
"Viewing Options and
157

Advertisement

Table of Contents
loading

Table of Contents