Linear Scale Technical Specifications - Renishaw RESOLUTE FS with BiSS Series Installation Manual And Safety Manual

Safety encoder system
Table of Contents

Advertisement

Linear scale technical specifications

RTLA30-S
Form
(H × W)
Accuracy
(at 20 °C)
(includes slope and linearity)
Supplied length
Material
Coefficient of thermal expansion
(at 20 °C)
Datum fixing
Mass
Installation temperature
Mounting
NOTE: For lengths > 2 m FASTRACK carrier with RTLA30 linear scale is recommended.
RTLA30
Form
(H × W)
Accuracy
(at 20 °C)
(includes slope and linearity)
Supplied length
Material
Coefficient of thermal expansion
(at 20 °C)
Datum fixing
Mass
Installation temperature
Mounting
FASTRACK carrier
Form
(H × W)
Minimum recommended length
Supplied length
Material
Coefficient of thermal expansion
(at 20 °C)
Installation temperature
Mounting
RESOLUTE FS with BiSS
Safety encoder system installation guide and safety manual
®
0.4 mm × 8 mm (including adhesive)
±5 μm/m
Calibrated traceable to International Standards.
20 mm to 21 m*
Hardened and tempered martensitic stainless steel fitted
with a self-adhesive backing tape
10.1 ± 0.2 μm/m/°C
Datum clamp (A-9585-0028) secured with Loctite 435
(P-AD03-0012)
14.6 g/m
15 °C to 35 °C
Self-adhesive backing tape
0.2 mm × 8 mm
±5 μm/m
Calibrated traceable to International Standards.
20 mm to 21 m*
Hardened and tempered martensitic stainless steel
10.1 ± 0.2 μm/m/°C
Loctite 435
12.2 g/m
15 °C to 35 °C
RTLA30 is held within the FASTRACK carrier system
0.4 mm × 18 mm (including adhesive)
100 mm
100 mm to 25 m
Hardened and tempered martensitic stainless steel fitted
with a self-adhesive backing tape
10 μm/m/°C
15 °C to 35 °C
(CTE
− CTE
) × ∆T × L
substrate
FASTRACK
Where ∆T is the temperature range between installation
and the extreme of operating or storage and L is the
scale length between datum and its furthest end.
NOTE: If there is more than ±1 mm of thermal
expansion mismatch in a system please contact
Renishaw for further assistance
Self-adhesive backing tape
RELA
Form
(H × W)
Accuracy
(at 20 °C)
(includes slope and linearity)
Supplied length
Material
Coefficient of thermal expansion
(at 20 °C)
Datum fixing
Mass
Mounting
RSLA
Form
(H × W)
Accuracy
(at 20 °C)
(includes slope and linearity)
Supplied length
Material
Coefficient of thermal expansion
(at 20 °C)
Datum fixing
Mass
Mounting
*
 The maximum scale length is determined by the readhead resolution and the number of position bits
in the serial word. For RESOLUTE FS with BiSS Safety readheads with fine resolution and short word
length, the maximum scale length will be limited accordingly. Conversely, coaser resolutions or longer
word lengths enable the use of longer scale lengths.
Resolution
Maximum scale length (L) with 36 bit position word
Maximum scale length (L) with 28 bit position word
Original instructions
1.6 mm × 14.9 mm
Certified to ±1 μm for lengths up to 1 m.
±1 μm/m for lengths > 1 m to 1.5 m.
Calibrated traceable to International Standards.
20 mm to 1.5 m
ZeroMet™. High stability low-expansion nickel-iron alloy
0.75 ± 0.35 μm/m/°C
RGG-2 epoxy (A-9531-0342) datum point
184 g/m
Adhesive backing tape (nominal thickness 0.2 mm)
1.5 mm × 14.9 mm
±1.5 μm for lengths up to 1 m
±2.25 μm/m for lengths from 1 m to 2 m
±3 μm/m for lengths from 2 m to 3 m
±4 μm/m for lengths from 3 m to 5 m
Calibrated traceable to International Standards
20 mm to 5 m
Hardened and tempered martensitic stainless steel
10.1 ± 0.2 μm/m/°C
RGG-2 epoxy (A-9531-0342) datum point
172 g/m
Adhesive backing tape (nominal thickness 0.2 mm)
1 nm
50 nm
21 m
N/A
N/A
13.421 m
29

Advertisement

Table of Contents
loading

Table of Contents