Alcatel-Lucent 1850 User Provisioning Manual page 537

Transport service switch
Table of Contents

Advertisement

Appendix
............................................................................................................................................................................................................................................................
Command
ED-USER-SECU
............................................................................................................................................................................................................................................................
8DG08763KAAA
Issue 1 February 2009
Description
User Identifier, specifies a unique
user ID.
User Identifier, specifies a unique
user ID.
New Password Identifier, specifies
the user's new login password.
User access privilege(s) granted to
this user.
This is the expiry duration for the
password. When a user logs in
after the PAGE period, he/she will
be notified with the details of the
PCNN and PCND. The user has to
change the password before the
PCND or the PCNN period. The
password aging time is in days.
Range is between 0 to 999 days.
Early warning on imminent
password aging. This is the
duration in number of days after
the PAGE, which is allowed for
the user to change his password.
The unit of PCND is in days.
Range is between 0 to 999 days.
This is the number of times that a
user can log in after PAGE limit
was reached and before which the
user has to change his password.
Range is between 0 to 999 times.
Password Obsolescence Interval.
This is the minimum time interval
that is required if the User wishes
to use a password that was already
used. Unit of POINT is in days.
Range is between 0 to 999 days.
User ID Aging Interval. This
parameter specifies the aging or
expiry interval of a particular User
Id. At the end of this interval, the
UID is disabled if during this
interval it has never been used to
set up a session. Range is between
0 to 999 days.
Parameter defaults
Parameter
Default
UID
Entry Required
NEWUID
Entry Required
NEWPID
Entry Required
UAP
READ
PAGE
<Previously
existing value>
PCND
<Previously
existing value>
PCNN
<Previously
existing value>
POINT
<Previously
existing value>
UOUT
<Previously
existing value>
6 - 1 4 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tss-320Tss-160

Table of Contents