Specifications
Environmental specifications
Specification
Temperature range
Operating
Non-operating
Relative humidity (noncondensing)
Operating
Non-operating
3
Altitude
Operating
Non-operating
1
The following temperature conditions and limitations apply:
•
All temperature ratings shown are for sea level.
•
An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) up to 3048 m (10,000 ft) applies.
•
No direct sunlight is allowed.
•
The maximum permissible rate of change is 10°C/hr (18°F/hr).
•
The type and number of options installed might reduce the upper temperature and humidity limits.
•
Operating with fan fault or above 30°C (86°F) might reduce system performance.
2
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F).
3
Maximum storage altitude corresponds to a minimum pressure o 70 kPa (10.1 psia).
Compute module physical specifications
The following details physical specifications for the HPE Synergy 480 Gen10 compute module.
Specification
Height
Depth
Width
Weight (maximum)
Weight (minimum)
1
2
Value
—
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
—
10% to 90% @ 28°C (82.4°F)
5% to 95% @ 38.7°C (101.7°F)
—
3050 m (10,000 ft)
9144 m (30,000 ft)
Value
63.60 mm (2.50 in)
606.50 mm (23.88 in)
214.00 mm (8.43 in)
8.16 kg (18.00 lb)
6.57 kg (14.50 lb)