Symptom
VIII
"
" does not appear on the
display and no action occurs
when an RS232 command is
sent from an external device.
IX
No feedback appears on the
RS232 Interface display when a
Master Control button is
pressed.
X
No feedback appears on the
RS232 Interface display when a
Dimmer, Switch, or GRAFIK Eye
Control Unit's level is changed
locally.
Possible Cause
RS232 Interface not programmed.
RS232 command is incorrect.
External device using incorrect
baud rate.
Master Control does not have a
Master Control Number.
Master Control button press
feedback is not turned ON.
Dimmer, Switch, or GRAFIK Eye
Control unit does not have a Zone
Number.
Local Zone Change feedback is
not turned ON.
RadioRA
Setup Guide Addendum for the RS232 Interface
®
Remedy
Program the RS232 Interface.
Verify command and parameters are
accurate.
Verify baud rate of external device is set to
9600 baud.
Verify Master Control Number, see
Assigning Master Control Numbers,
page 29.
Verify Master Control button press
feedback is turned ON, see the RadioRA
RS232 Protocol and Programming Guide
(P/N 044-006).
Verify Zone Number, see Assigning Zone
Numbers, page 26.
Verify Local Zone Change feedback is
turned ON, see the RadioRA RS232
Protocol and Programming Guide
(P/N 044-006).