Phantom SCENE Button Programming
Step 5
Complete setting light levels/
GRAFIK Eye scene selection
Press and hold the Level Set button until all
the LEDs begin to flutter (approximately 3
seconds).
and o erating instructions.
Level Set LED – OFF
(800) 523-9466
For additional assistance call the Lutron Hotline:
RadioRA is a trademark of Lutron Electronics Co. Inc.
This product may be covered by one or more of the following
U.S. patents: 5,248,919; 5,399,940; 5,736,965; 5,798,581;
5,838,226; 5,848,054; 5,905,442, 5,982,103
Up
TX
RX
Down
Select
Level Set Mode
Level Set LED will turn OFF and the display
will stop flashing.
If at any point in this procedure you are unsure
which Dimmers, Switches or GRAFIK Eye
Control Units are assigned to an RS232
Interface Phantom SCENE Button:
• While the display is flashing, press and hold
the Select button (approximately 3 seconds).
• The Level Set LED will begin to flash and all
Dimmers, Switches, and GRAFIK Eye
Control Units assigned to that RS232
Interface Phantom SCENE Button will turn
ON to full intensity.
Note: Dimmer, Switch or GRAFIK Eye
Control Unit assignments cannot be
changed at this time. See page 20 to
change control assignment.
• Press the Select button again to continue
setting light levels. The Level Set LED will
stop flashing.
Assignment Mode
Power
RadioRA
Note: To access scenes 5-16 on a GRAFIK
?
Eye Control Unit, refer to Application Note #48
(P/N 366-730).
Setup Guide Addendum for the RS232 Interface
®