13.  TROUBLES THAT DO NOT DISPLAY THE TROUBLE CODE
13.1  Machine is not energized at all (DCPU operation check) (bizhub C658/C558/C458/C368/C308/C258)
13.1.1  Contents
Trouble type
Machine is not energized at all
Rank
-
Trouble detection condition -
Trouble isolation
-
Relevant electrical parts
13.1.2  Procedure
Step
1
Is a power voltage supplied across CN1-1 and 2
on DCPU?
2
Are the fuses on DCPU conducting?
3
Is DC5 V being output from CN6-5 on DCPU?
4
Is DC24 V being output to CN7-3 on DCPU?
5
The LED on MFPB is blinking?
6
Is DC24 V being output to CN7-1 on DCPU?
N.1 bizhub C368/C308/C258
N.2 bizhub C658/C558/C458
13.2  Fusing heaters do not operate (bizhub C658/C558/C458/C368/C308/C258)
13.2.1  Contents
Trouble type
Fusing heaters do not operate
Rank
-
Trouble detection condition -
Trouble isolation
-
Relevant electrical parts
13.2.2  Procedure
Step
1
Is a power voltage supplied across CN8-5 on
DCPU?
During this time, the right door should be closed.
2
Is the power source voltage applied across
MFPB CN13E-6, 9? (bizhub C368/C308/C258)
3
Is the power source voltage applied across
MFPB CN13E-4, 6 (bizhub C658/C558), MFPB
CN12E-6, 9 (bizhub C458)? (bizhub C658/C558/
C458)
K TROUBLESHOOTING > 13. TROUBLES THAT DO NOT DISPLAY THE TROUBLE
• Main power switch (SW1)
• MFP board (MFPB)
• DC power supply (DCPU)
Check item
• Main power switch (SW1)
• Right door switch (SW3)
• DC power supply (DCPU)
• MFP board (MFPB)
• Fusing unit
Check item
Location of electrical
Result
component
C368/C308/C258
NO
19-T
C658/C558/C458
15-S
-
NO
C368/C308/C258
NO
19-R
C658/C558/C458
17-S
C368/C308/C258
NO
19-R
C658/C558/C458
18-S
-
NO
C368/C308/C258
NO
19-R
C658/C558/C458
18-S
Location of electrical
Result
component
C368/C308/C258
NO
17-R
C658/C558/C458 15
to 16-Q
C368/C308/C258
YES
11-E
NO
C658/C558/C458 23
YES
to 24-C
NO
K-291
Action
Check the WIRING from the wall outlet to
SW1 to CN1.
Replace DCPU.
(bizhub C368/C308/
C258
/
bizhub
C658/C558/C458)
Replace DCPU.
(bizhub C368/C308/
C258
/
bizhub
C658/C558/C458)
• Check the WIRING from the wall
MFPB to DCPU.
• Replace DCPU.
(bizhub C368/C308/
C258
/
bizhub
C658/C558/C458)
• Replace MFPB.
(bizhub C368/C308/
C258
/
bizhub
C658/C558/C458)
Replace MFPB.
(bizhub C368/C308/
C258
/
bizhub
C658/C558/C458)
Replace DCPU.
(bizhub C368/C308/
C258
/
bizhub
C658/C558/C458)
Action
Check wiring from power outlet to SW1 to
CN8 to SW3.
Replace the fusing unit.
Replace DCPU.
Replace MFPB.
Replace the fusing unit.
(bizhub C658/
C558
/
bizhub
C458)
Replace DCPU.
Replace MFPB.