Konica Minolta bizhub C658 Service Manual page 1516

Hide thumbs Also See for bizhub C658:
Table of Contents

Advertisement

bizhub C658/C558/C458/C368/C308/C258
(2)  Procedure
1. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. If no problems are encountered, HDD Mirroring Rebuild is
automatically performed.
2. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Status] and identify the specific hard disk that has developed the error.
If an error occurs, "Error" appears in the status column.
3. Replace the hard disk that has developed the error with a new one.
C458)
/
HDD (B) (bizhub C368/C308/C258)
4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform physical format.
5. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform logical format.
6. If HDD Data Backup has previously been performed, select [Service Mode] -> [Enhanced Security] -> [HDD Data Backup] -> [Restore]
and perform the function.
7. If HDD Data Backup has not been performed previously, install voice data, etc.
3.24.11  CD017 (bizhub C658/C558/C458/C368/C308/C258)
(1)  Contents
Trouble type
Rank
Trouble detection condition A R/W error occurs in the slave drive during HDD Mirroring Rebuild.
Trouble isolation
Relevant electrical parts
(2)  Procedure
1. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON. If no problems are encountered, HDD Mirroring Rebuild is
automatically performed.
2. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Status] and identify the specific hard disk that has developed the error.
If an error occurs, "Error" appears in the status column.
3. Replace the hard disk that has developed the error with a new one.
C458)
/
HDD (B) (bizhub C368/C308/C258)
4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] ->
3.24.12  CD030 (bizhub C658/C558/C458/C368/C308/C258)
(1)  Contents
Trouble type
Rank
Trouble detection condition The machine fails to read administrative information data saved in the hard disk.
Trouble isolation
Relevant electrical parts
3.24.13  CD041, CD042, CD043, CD044, CD045, CD046 (bizhub C658/C558/C458/C368/C308/C258)
(1)  Contents
Trouble type
Rank
Trouble detection condition The error occurred inside the hard disk.
Trouble isolation
Relevant electrical parts
(2)  Procedure
1. Check the hard disk specifications.
2.
Format the hard disk.
3. Replace the hard disk.
HDD (B) (bizhub
C658/C558/C458))
3.24.14  CD047, CD048, CD049, CD04A, CD04B (bizhub C658/C558/C458/C368/C308/C258)
(1)  Contents
Trouble type
Rank
Trouble detection condition The error occurred inside the hard disk.
Trouble isolation
Relevant electrical parts
• Hard disk (B) (HDD (B): HD-524)
/
HDD (B) (bizhub
CD017: HDD mirroring error slave (rebuild)
A
-
• Hard disk (A) (HDD (A))
• Hard disk (B) (HDD (B): HD-524)
/
HDD (B) (bizhub
CD030: Hard disk management information reading error
C
-
• Hard disk (A) (HDD (A))
• Hard disk (B) (HDD (B): HD-524)
CD041, CD042, CD043, CD044, CD045, CD046: HDD command execution error
C
-
• Hard disk (A) (HDD (A))
• Hard disk (B) (HDD (B): HD-524)
(HDD (A) (bizhub C368/C308/C258)
CD047, CD048, CD049, CD04A, CD04B: HDD SCSI library error
C
-
• Hard disk (A) (HDD (A))
• Hard disk (B) (HDD (B): HD-524)
(HDD (A) (bizhub C368/C308/C258)
C658/C558/C458))
(HDD (A) (bizhub C368/C308/C258)
C658/C558/C458))
[HDD Mirroring
/
HDD (A) (bizhub C658/C558/C458)
K-188
K TROUBLESHOOTING > 3. TROUBLE CODE
/
HDD (A) (bizhub C658/C558/
/
HDD (A) (bizhub C658/C558/
Rebuild] and perform the function.
/
HDD (B) (bizhub C368/C308/C258)
/

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents