(a)  Service Mode
[Machine/Fusing
Temperature]
• [Machine/Heater Control Level].
• [System 1/Warmup]
• [System
2/Smart Fusing
(b)  Enhanced Security
• [Engine FW DipSW / No.5
• [Engine FW DipSW / No.13
13.3.6  Plain paper fusing temperature control
• Two different target temperatures control the printing on plain paper.
Basis weight
2
Plain paper (60g/m
- 70g/
The base weight is limited to 60g/m
2
m
)
target temperature to lower than the normal fusing temperature.
2
Plain paper (60g/m
- 90g/
The normal target temperature controls the fusing temperature control of plain paper.
2
m
)
(1)  Setting procedure
Example of display
1. Select [Paper] on the basic screen.
2. Select your desired paper feed port and tap [Change Tray Setting].
3. Select [Plain Paper] and tap [Alter Paper Thickness] to select "Plain Paper (60g/m2 - 70g/m2)".
A "check mark" will be displayed in the check box of the [Alter Paper Thickness] key.
4. Tap the [Alter Paper Thickness] key again to select "Plain Paper (60g/m2 - 90g/m2)".
The "check mark" in the check box of the [Alter Paper Thickness] key will disappear.
NOTE
▪ "Plain Paper (60g/m2 to 70g/m2)" is specified by default only for Japan.
▪ You can only use the [Alter Paper Thickness] key for plain paper.
13.3.7  Smart fusing control
• Lower the target temperature as much as possible according to the information of each sheet of paper to control the fusing temperature
adjustment. In this way, the power consumption
• Smart fusing control is only performed when the execution conditions below are met.
• If these execution conditions are not met, the normal fusing temperature control is performed.
• Smart fusing control can also prohibit control execution from [Service Mode] -> [System 2] -> [Smart Fusing Control].
For details on how to configure the settings, see "
(1)  Smart fusing control execution conditions
Temp-Inside
Print mode
Basic Settings
Print zoom
Paper type
Layout
Combination
Image shift
Cover sheet
Cover sheet
insertion
Back cover
Inter sheet
OHP interleave
Control]
Choice of high humidity
circumstance]
Choice of securing
fusibility]
(TEC
value) is controlled.
I.5.16.35 Smart Fusing
Function
O THEORY OF OPERATION bizhub C658/C558/C458/C368/C308/C258 > 13.
FUSING SECTION (bizhub C458/C368/C308/C258)
Specific controls
2
2
- 70g/m
. Power consumption (TEC value) is controlled through lowering the
Control".
10 °C and above
Only for PC printing, BOX printing, and direct printing (USB)*1
Only 100%
Plain paper only
1 in 1 only
No
No
No
No
No
O-106
Execution conditions