Konica Minolta bizhub C658 Service Manual page 1534

Hide thumbs Also See for bizhub C658:
Table of Contents

Advertisement

bizhub C658/C558/C458/C368/C308/C258
4. Correct the mounting of the connection cable if faulty.
5. Replace the connection cable.
6. Replace the wireless LAN board.
7. Replace the Wireless LAN module.
8. Replace the MFP board.
4.16  E5-13
Description
Error code
E5-13
Target device
Various USB devices
Diagnosis item
Authentication unit
Reason of error
Connection failure
Parts defect
Relevant parts
Authentication unit
MFP board (MFPB)
Corrective action procedure
1. Turn OFF the main power switch, disconnect power cord from the outlet.
2. Correct the mounting and connection of the authentication unit if faulty.
3. Correct the mounting of the MFP board or the connection of connectors if faulty.
4. Replace the authentication unit.
5. Replace the MFP board.
4.17  E6-1, E6-2
Description
NOTE
▪ When executing the Self-diag. (Full) after the trouble code (C6###, C91##) is displayed, the self diagnosis may not complete. In
that case, finish the Self-diag. (Full) forcibly, and perform the troubleshooting against the trouble code.
▪ Turning OFF the main power switch will finish the Self-diag. (Full) forcibly.
Error code
E6-1, E6-2
Target device
CCD board
Diagnosis item
E6-1
E6-2
Reason of error
E6-1
E6-2
Relevant parts
Connection cable
CCD board (CCDB)
MFP board (MFPB)
Corrective action procedure
1. Turn OFF the main power switch, disconnect power cord from the outlet.
2. Correct the mounting of the CCD board and the connection cable if faulty.
3. Correct the mounting of the MFP board or the connection of connectors if faulty.
4. Replace the connection cable.
5. Replace the CCD unit.
6. Replace the MFP board.
4.18  E7-1, E7-2
Description
NOTE
▪ When executing the Self-diag. (Full) after the trouble code (C6###, C91##) is displayed, the self diagnosis may not complete. In
that case, finish the Self-diag. (Full) forcibly, and perform the troubleshooting against the trouble code.
▪ Turning OFF the main power switch will finish the Self-diag. (Full) forcibly.
Error code
E7-1, E7-2
Target device
CCD board
Diagnosis item
E7-1
E7-2
Reason of error
E7-1
E7-2
Relevant parts
CIS cable
CIS module (CIS)
DS image processing board (DSIPB)
Corrective action procedure
1. Turn OFF the main power switch, disconnect power cord from the outlet.
2. Correct the mounting of the CIS module and the CIS cable if faulty.
3. Correct the mounting of the DS image processing board or the connection of connectors if faulty.
4. Replace the CIS cable.
O/P Image Bus Check
Line RAM Comparison
Image bus failure
CCD sensor failure
O/P Image Bus Check
Line RAM Comparison
Image bus failure
CIS sensor failure
K-206
K TROUBLESHOOTING > 4. Troubleshooting using Self-diag. (Full)

Hide quick links:

Advertisement

Table of Contents
loading