bizhub C658/C558/C458/C368/C308/C258
2. Rewrite the firmware.
3.
Replace DSIPB.
4.
Replace MFPB.
3.24.45  CDF51, CDF71, CDFA1 (bizhub C658/C558/C458)
(1)  Contents
Trouble type
Rank
Trouble detection condition Communication error is detected between the MFP board (MFPB) and the dual scan image processing board
Trouble isolation
Relevant electrical parts
(2)  Procedure
1. Check the connector between MFPB CN24-DSIPB CN1 for proper connection and correct as necessary.
2. Update the firmware.
3.
Replace DSIPB.
4.
Replace MFPB.
3.25  CE###
3.25.1  CE001, CE003, CE004, CE005, CE006, CE007, CE009 (bizhub C658/C558/C458/C368/C308/C258)
(1)  Contents
Trouble type
Rank
Trouble detection condition MFP board (MFPB) is faulty.
Trouble isolation
Relevant electrical parts
(2)  Procedure
1. Check the connectors on MFPB for proper connection and correct as necessary.
2. Replace MFPB.
(bizhub C368/C308/C258
3.25.2  CE002 (bizhub C658/C558/C458/C368/C308/C258)
(1)  Contents
Trouble type
Rank
Trouble detection condition MFP board (MFPB) is faulty.
Trouble isolation
Relevant electrical parts
(2)  Procedure
1. Turn OFF the main power switch and turn it ON again, and conduct the following setting. [Service Mode] -> [System 1] -> [Initialization] -
>
[Clear All
Data].
2.
Format the hard disk.
3. Replace the hard disk.
HDD (B) (bizhub
C658/C558/C458))
4. Replace MFPB.
(bizhub C368/C308/C258
3.25.3  CE101 (bizhub C658/C558/C458/C368/C308/C258)
(1)  Contents
Trouble type
Rank
Trouble detection condition
• CDF51: ASIC image version failure (back side)
• CDF71: ASIC image access failure (back side)
• CDFA1: ASIC image error (back side)
C
(DSIPB).
-
• MFP board (MFPB)
• Dual scan image processing board (DSIPB)
• CE001: Abnormal message queue
• CE003: Task error
• CE004: Event error
• CE005: Memory access error
• CE006: Header access error
• CE007: DIMM initialize error
• CE009: Memory resource shortage error
C
-
MFP board (MFPB)
/
bizhub
C658/C558/C458)
CE002: Message and method parameter failure
C
-
• MFP board (MFPB)
• Hard disk (A) (HDD (A))
• Hard disk (B) (HDD (B): HD-524)
(HDD (A) (bizhub C368/C308/C258)
/
bizhub
C658/C558/C458)
CE101: Browser finish detected
C
• The browser is automatically recovered (restarted) after the main body detected that the browser (separate
process) has stopped with fault.
/
HDD (A) (bizhub C658/C558/C458)
K-197
K TROUBLESHOOTING > 3. TROUBLE CODE
/
HDD (B) (bizhub C368/C308/C258)
/