Konica Minolta bizhub C658 Service Manual page 1539

Hide thumbs Also See for bizhub C658:
Table of Contents

Advertisement

bizhub C658/C558/C458/C368/C308/C258
6.2.2  Procedure
• When an abort code occurs, take a check and action in the following procedure.
Step
Section
1
Main power
Turn OFF and ON the main power switch, and check if
switch
the Abort code appears again.
2
Connector
Check the connector for proper connection and correct
connection
as necessary.
3
Firmware
Update the firmware to the latest version, and check if
the Abort code appears again.
4
Memory Check Execute [Service Mode] -> [State Confirmation] ->
[Memory/Storage Adjustment] -> [Memory Check] ->
[Rough Check], and check that no abnormalities.
5
Storage R/W
Execute [Service Mode] -> [State Confirmation] ->
Check
[Memory/Storage Adjustment] -> [Storage R/W Check],
and check that no abnormalities.
6
MFP board
Replace the MFP board (MFPB), and then check the
MFPB.
6.3  CF0##
Error code
CF001
CF004
CF011
CF012
CF013
CF021
CF023
CF033
CF061
CF062
6.4  CF1##
Error code
CF112
CF113
CF122
6.5  CF2##
Error code
CF211
• EFI relay board (VI-510)
• Dual scan image processing board (DSIPB)
• Hard disk (A) (HDD (A))
• Hard disk (B) (HDD (B): HD-524)
Check Item
• MFP board (MFPB)
• EFI relay board (VI-510)
• Dual scan image processing board (DSIPB)
• Hard disk (A) (HDD (A))
• Hard disk (B) (HDD (B): HD-524)
CT_singleList table abnormal
CT_queue full abnormal
Array link abnormal
FAT link abnormal
File size abnormal
setDelayMessage Table OverFlow
MsgQue OverFlow
setDivTbl() limitation over
IdeCommand_Set() status
Abnormal
IdeCommand_Set() parameter
Abnormal
Compress table OverFlow
Compress table check
Expand Table OverFlow
setParameterBandColorPlane()
Table OverFlow
Resul
t
NO
NO
NO
NO
NO
NO
Item
An exceptional instance occurred
due to the unexpected parameter
in the system F/W.
Item
Compression malfunctions
Item
An exceptional instance occurred
due to the unexpected parameter
in the system F/W.
K-211
K TROUBLESHOOTING > 6. ABORT CODE
Action
When not reappearing, continuous use is carried
out, and it is checked whether an abort code
occurs.
It will correct, if connector connection has
abnormalities.
Select [Service Mode] ->
[Firmware
make sure that the firmware has been updated to
the correct version.
When "NG" is displayed, replace the appropriate
memory or PWB.
• WORK0: Standard memory (MFPB)
• WORK1: Expansion memory
• FILE0,1: MFP board (MFPB)
• FILE2,3: EFI relay board (VI-510)
• FILE4,5: Dual scan image processing board
(DSIPB)
When "NG" is displayed, replace the hard disk
(HDD).
Other electric parts indicated to Component of
abort code list are replaced.
Component
MFP board (MFPB)
Component
MFP board (MFPB)
Component
MFP board (MFPB)
Version] and
Rank
C
Rank
C
Rank
C

Hide quick links: