Container variables for VGA MB-Panels

Container variables, available to the user, are included in the firmware of these terminals.
Containers let the application program exchange information with the firmware. All
container variables have the prefix «uBT_».
Be careful, these functions are «case sensitive»
It might be that the version of this manual does not correspond with the Up-to-date
version of the user's guide which is the references document regarding this list of
container variable. If you have a malfunction or a doubt regarding this list, we recom-
mend using the reference list (in english) of the user's guide 26-858 E (up-to-date
version is on the support site) which is more regulary updated.
Config
Container
file
(Source HN
entry
10.03.10)
R/W
uBT_AlarmFre-
quency *
no
uBT_AlarmStart *
R/W
uBT_AlarmVol-
ume *
R/W
uBT_AutoRepeat
* Acoustic Alarm: see also the Appendix B
Manual PCD7.D4xx │  D ocument 26-851 ENG12  │   2 016-02-05
Type
Default
Decimal
1000
value
String
Decimal
0
value
string
Decimal
10
value
string
Boolean
0
value
string
Min
Max
Description
Value
Value
Min
Max
Length
Length
125
8000
Frequency setting of the acoustic
alarm (Hz)
(Rounded down to 125, 250, 500,
1000, 2000, 4000, 8000)
Use this before starting the alarm.
Renewed setting during running
alarm will be first used at the next
start of the alarm.
0
30000:
Write a value to start or stop the
30 s
pulsed acoustic alarm.
The acoustic alarm can be started
with a setting of the interval time
(0...30000 ms) of the pulsed signal.
A 50% duty cycle is used with
pulse time equal to pause time.
If already running a renewed set-
ting is ignored. Setting it to 0 how-
ever switches it off immediately.
The alarm also stops by any touch
on the screen.
0
20:
Acoustic alarm volume setting
100%
(0...20).
As pulse width modulation is used
to control the volume this setting
has an influence on the sensed
pitch of the alarm.
Use this before starting the alarm.
Renewed setting during running
alarm will be first used at the next
start of the alarm.
0
1
At Soft Input Panel SIP (keyboard
on the screen) use:
SIP Key board: Autorepeat on(1),
off (0)
Update & special settings
Special internal Functions
6
6-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcd7.d435 seriesPcd7.d457 seriesPcd7.d410vtcf

Table of Contents