SBC D443WTPR Manual

Room web panel pcd7.d443wtxrx series
Table of Contents

Advertisement

Quick Links

Manual
Room Web Panel
PCD7.D443WTxRx
Document 27-644 │ Version ENG04 │ 2017-10-30

Advertisement

Table of Contents
loading

Summary of Contents for SBC D443WTPR

  • Page 1 Manual Room Web Panel PCD7.D443WTxRx Document 27-644 │ Version ENG04 │ 2017-10-30...
  • Page 2: Table Of Contents

    Saia-Burgess Controls AG Inhalt Quick start ............................. 6     Introduction ..........................6     Definition of connections ......................7     Power supply for the panel / (*RS-485) ..................7     Device dimensions and cut-out ....................8    ...
  • Page 3 Saia-Burgess Controls AG 5.1.2 TCP/IP address ........................24     5.1.3 Subnet mask ........................24     5.1.4 Default gateway ........................24     5.1.5 DNS on ..........................24     5.1.6 Primary DNS server ......................24     5.1.7 Secondary DNS server ......................
  • Page 4 Saia-Burgess Controls AG Connect via FTP access ......................32     Update and special settings ......................33     Firmware update ........................33     7.1.1 Additional information regarding FW download ..............33     7.1.2 Secure firmware download via USB..................33  ...
  • Page 5 Saia-Burgess Controls AG Document versions Version Publication Changes Comments EN01 2016-11-28 First version of manual EN02 2016-12-02 HW(B)Sen- Update HW B and FW > 1.28.04 sor/LED EN03 2017-05-24 Pictures white Version ENG04 2017-10-30 Small adaptions Trademarks Saia PCD is a registered trademark of Saia-Burgess Controls AG. ®...
  • Page 6: Quick Start

    Saia-Burgess Controls AG Quick start Introduction This handbook deals with the technical aspects of the PCD7.D443WTxRx Room Web Panel family. The Quick start chapter is designed to ensure optimum installation of the PCD7.D443WTxRx series. Remark: The small "x" in the product name are placeholders and stand for any digit or letter to draw attention to device variants.
  • Page 7: Definition Of Connections

    Saia-Burgess Controls AG Definition of connections Power supply for the panel / (*RS-485) Connection pins Signal 24V DC (+) GND (-) Supply voltage: (RS-485) 24 V +20% / -20% GND (-) (RS-485) (RS-485) * available only on PCD7.D443WT5Rx Power Power without back- Power with back- PCD7.D443WTPRx Max.
  • Page 8: Device Dimensions And Cut-Out

    Saia-Burgess Controls AG Device dimensions and cut-out 1.4.1 Device dimensions Dimensions in Front panel W x H 90 x 152 Display W x H 55 x 96 Cut-out W x H 83 x 140 In the sideview can be seen, that some components are protruding out of the mounting frame. That means they go a few millimeters under the surface of the wall plaster. ...
  • Page 9: Dimensions Of Mounting Adapter

    Saia-Burgess Controls AG 1.4.2 Dimensions of mounting adapter The adapter is mounted on the wall installation box using 4 enclosed Torx T8 screws. Dimensions in Front panel W x H 85 x 147 The adapter can be mounted on standard double wall installation boxes. PCD7.D443WTxRx | Document 27-644 | Version ENG04 | 2017-10-30...
  • Page 10: Mounting The Panels

    Saia-Burgess Controls AG Mounting the panels The panel is mounted with the help of the adapter contained in the package on standard double wall installation boxes. E.g. Electro-Material Art. No. L 8102 HSB-Weibel AG Art. No. 372 104 747 Agro Art. No. 9922 Blass-Elektro Art.
  • Page 11 Saia-Burgess Controls AG Lower it into the adapter and .. then push it down. The panel will now lock in the adapter. Remark: The mounting and removing of the panel described below refers to panels with hardware version B or later. For the panels with hardware version A, the locking ratchet was on the upper right side of the housing.
  • Page 12 Saia-Burgess Controls AG To remove the panel from the adapter Press on the locking ratchet using a screwdriver at the same time push the panel upwards. and .. Lift the panel out of the adapter and .. remove it from the adapter. PCD7.D443WTxRx | Document 27-644 | Version ENG04 | 2017-10-30...
  • Page 13: Mounting Location

    Saia-Burgess Controls AG 1.5.1 Mounting location  The device can be mounted horizontally or vertically.  To ensure the most accurate temperature measurement possible, check that the sensor is not affected by any external influences when choosing a mounting location. Do not expose the panel to di- rect sunlight or lighting.
  • Page 14: Setting Up Communication To Display A Web Page

    Saia-Burgess Controls AG Setting up communication to display a web page 1.6.1 HTTP direct via Ethernet RJ45 connection The quickest communication connection is the Ethernet port via RJ45, if the protocol HTTP direct was selected. The speed is either 10 MBit/s or 100 MBit/s with an auto-negotiation protocol via the connected device.
  • Page 15: Usb Port As Service Port

    Saia-Burgess Controls AG 1.6.3 USB port as service port With the PCD7.D443WT5Rx panels, the USB port is used to load the user program with PG5 onto the controller. With the PCD7.D443WTPRx panels, this port generally serves as a service port. It is mainly used to load new firmware programs onto the device.
  • Page 16: Technical Data For The Two Panel Types

    Technical data for the two panel types Because of the programmable logic controller in the programmable panels, the hardware of the PCD7.D443WTPR and PCD7.D443WT5R Micro Browser Panels differs in certain respects. These differences are described in the following sections. Status display, sensors and actions PCD7.D443WTPRx...
  • Page 17: Technical Data For The Room Micro Browser Panel

    Saia-Burgess Controls AG Technical data for the Room Micro Browser Panel PCD7.D443WTPRx PCD7.D443WT5Rx Display Colours 65 K 65 K Display 4.3" TFT 4.3" TFT Resolution/pixels QWVGA / 480 x 272 pixels QWVGA / 480 x 272 pixels Touchscreen PCAP technology PCAP technology Adjustable contrast Yes, 20 levels...
  • Page 18: Logic Controller For The Pcd7.D443Wt5Rx Programmable Panels

    Saia-Burgess Controls AG Logic controller for the PCD7.D443WT5Rx programmable panels Communications interfaces The programmable logic controller has various built-in communications interfaces. 3.1.1 RS-485 on board PCD4.D443WT5R PCD3.Mxxxx PCD2.M5xxx PCD1.M2xxx Ensure that the terminals are terminated correctly. The example below shows a possible connection between the terminals and the PCDs. In order to avoid reflection on the communication channel, the network should be equipped with terminators.
  • Page 19: Configuring The Hardware Settings In Pg5 (Pcd7.D443Wt5Rx)

    Saia-Burgess Controls AG Configuring the hardware settings in PG5 (PCD7.D443WT5Rx) Generally speaking, the PCD7.D443WT5Rx is configured via PG5 in which the project too is cre- ated. However, it can also be carried out on the panel itself via the Setup Menu described in Chap- ter 4.
  • Page 20: Software Watchdog (Pcd7.D443Wt5Rx)

    Saia-Burgess Controls AG Software watchdog (PCD7.D443WT5Rx) The PCD7.D443WT5R panels have a software watchdog where the processor monitors itself and the CPU is restarted in the event of a malfunction or a loop. The core of the software watchdogs is the instruction SYSWR K 1000. When this is output for the first time, the watchdog function will be enabled.
  • Page 21: Using The Panel's Setup Menu

    Saia-Burgess Controls AG Using the panel's Setup Menu This chapter describes the menu structure of the PCD7.D443WTxRx Micro Browser Panel. Opening the Setup Menu Bringing up the Setup Menu: By pressing and holding any area (excluding buttons) for 4 seconds at any time →...
  • Page 22: Saving And Exiting

    Saia-Burgess Controls AG Saving and exiting If you change one or more parameters, you must confirm whether you want to save the changes, save and reboot or revert to the old parameters without saving the new ones. PCD7.D443WTxRx | Document 27-644 | Version ENG04 | 2017-10-30...
  • Page 23: Structure And Description Of The Setup Menu

    Saia-Burgess Controls AG Structure and description of the Setup Menu The Setup screen is the first screen that is shown when you bring up the Setup Menu. Network Chapter MB Panel settings Web connection Configuring the web connection Chapter System Info/Settings/Special/Download FW and Chapter reboot...
  • Page 24: Network

    Saia-Burgess Controls AG Network The network settings for the panel are configured here. Depending on the network, the connection works without setting a gateway or DNS server. You can exit the menu using the Setup button. With the programmable panels, the network configuration is generally carried out via the PG5 Device Configurator.
  • Page 25: Web Connection

    Saia-Burgess Controls AG Web connection The data for the device which loads and displays the web page are set here. With the programmable panels, this is normally the internal controller. The local host IP address must therefore be set to 127.0.0.1.
  • Page 26: System

    Saia-Burgess Controls AG System 5.3.1 Info System info such as firmware version, booter version… Firmware version → The firmware version currently installed on the panel Booter version → The booter version currently on the panel CPLD version → The current CPLD version on the panel →...
  • Page 27: Special

    Saia-Burgess Controls AG server before the PCD server is searched. Files will be searched for in the INTFLASH/web pages first o Remote before local "Remote before local" means that files (.teq, .gif … ) will be searched for on the remote server before the local server of the MB Panel is searched.
  • Page 28: Log

    Saia-Burgess Controls AG Show runtime infos → Advanced command for the runtime FTP server → Allows you to enable/disable the FTP server, define the FTP port, FTP users, timeout, con- → nections and default users Calibrating the temperature sensor → Allows you to enter a temperature value which was measured by an external device.
  • Page 29: Screen

    Saia-Burgess Controls AG Screen 5.4.1 Brightness Can be set to a value between 0 and 20 5.4.2 Gamma Gamma correction can be set to a value between 0.01 and 4.0 5.4.3 Background lighting [min] If the touchscreen or keys are inactive during this period, the background lighting will be switched off. The background lighting will be reactivated when the screen or a key is pressed.
  • Page 30: Keyboard

    Saia-Burgess Controls AG Keyboard 5.5.1 SIP (virtual keyboard) Enable/disable SIP (Soft Input Panel). Virtual keyboard 5.5.2 Keyboard compatible SIP 5.5.3 Name of the first keyboard: To be used if the panel is installed vertically: alphapad.teq (alphanumeric) or keypad.teq (numeric) opened as first keyboard. To be used if the panel is installed horizontally: alphapad90.teq (alphanumeric) or keypad90.teq (numeric) opened as first keyboard.
  • Page 31: Password

    Saia-Burgess Controls AG Password You can enter an alphabetical, numeric or alphanumeric password (maximum number of characters = 32, incl. spaces) You must confirm the password when entering it. If you enter a new password, you must confirm it. If the characters entered for confirmation purposes do not match, the old password will be retained.
  • Page 32: Local Files / Local Server

    Saia-Burgess Controls AG Local files / local server Connect via FTP access The internal structure can only be brought up via FTP: Saia file system (ftp access: User name and password). ftp:// IP address FILECACHE Contains the cache memory INTFLASH Contains: ...
  • Page 33: Update And Special Settings

    Saia-Burgess Controls AG Update and special settings Firmware update 7.1.1 Additional information regarding FW download If problems occur when downloading via USB, try the following solution: Restart the MB Panel with the USB cable removed. Press the Download button and the MB Panel's download mode will be enabled.
  • Page 34: Background Lighting

    Saia-Burgess Controls AG 3) With the button still pressed, switch on the MB Panel and keep the reset button pressed for a further 90 sec. 4) The firmware will recreate the file systems. In the process, the panel may not react for 1 to 2 minutes.
  • Page 35: Internal Special Functions

    Saia-Burgess Controls AG It is recommended that you use text fields which exceed the size shown in the editor by up to 20%. To determine the text field length, you can use the table for min. and max. x sizes below. General recommendations for the Y size in relation to the font size and format Basic rule: the text should lie WITHIN the contours.
  • Page 36 Saia-Burgess Controls AG Read/ Internal variable INT Type Standard Min. Max. Description write value value Min. Max. length length uBT_Gesture Decimal Gesture recognition: Swiping value string 0: No result 1: Swiping to the right 2: Swiping upwards 3: Swiping to the left 4: Swiping downwards uBT_Tap Decimal...
  • Page 37: User Led

    Saia-Burgess Controls AG 7.5.2 User LED The user LED can be used once the user has successfully started the firmware and application with the help of the internally reserved INT variable "uBT_Watch,UserLed". Read/ Internal variable INT Type Standard Min. Max. Description write value...
  • Page 38: Temperature Sensor

    Saia-Burgess Controls AG 7.5.3 Temperature sensor The panel features an internal temperature sensor. The temperature value currently measured is made available in the internal system variable INT uBT_Watch,Temperature,value for the user appli- cation in Web Editor 8. Read/ Internal variable INT Type Standard Min.
  • Page 39 Saia-Burgess Controls AG The temperature value can be passed on to the controller by Web Editor 8 for the user ap- plication with the following steps: 1) First of all, a background page for all pages in your project should be set up for the project.
  • Page 40 Saia-Burgess Controls AG IMPORTANT: To ensure that the value is overwritten by other display devices that do not have the temperature sensor, it is a good idea to set up an additional condition. If the value uBT_Watch,Tempera- ture,value is "empty" or has the default value defined in the WVAR, the function will not be exe- cuted.
  • Page 41: Container (Int) Variable For Room Mb Panel

    Saia-Burgess Controls AG E.g. the content of MB_PERCO_1 on Panel 1 corresponds to the value "1". In this case, the value with the symbolic name Example.RoomPanel.Temp.Array_1 will be written. E.g. the content of MB_PERCO_1 on Panel 2 corresponds to the value "5". In this case, the value with the symbolic name Example.RoomPanel.Temp.Array_5 will be written.
  • Page 42 Saia-Burgess Controls AG Read/ Internal INT variables Type Standard Min. Max. Description write (Container) value value Min. Max. length length uBT_BackLightTimeout Decimal 5000 Time (min) until the background lighting is value string switched off. When the screen is touched or when switching on via containers, the background lighting is switched on and the countdown begins.
  • Page 43 Saia-Burgess Controls AG Read/ Internal INT variables Type Standard Min. Max. Description write (Container) value value Min. Max. length length uBT_EnableCache Boolean 1 (Ena- File cache is used (1), 0 no file cache for value string bled) all visualisation files that are not images. Files are cached for the first time as soon as they are used.
  • Page 44 Saia-Burgess Controls AG Read/ Internal INT variables Type Standard Min. Max. Description write (Container) value value Min. Max. length length uBT_IntroGraphicName ANSI text SaiaSU Start graphic string Grande. uBT_IntroGraphicXPos Decimal Position of the start graphic value string (Horizontal position from the left) uBT_IntroGraphicYPos Decimal Position of the start graphic...
  • Page 45 Saia-Burgess Controls AG Read/ Internal INT variables Type Standard Min. Max. Description write (Container) value value Min. Max. length length uBT_PressX Decimal Gesture recognition; press recognition on value string touchscreen X coordinate Contains the X coordinate if the press gesture recognition was activated uBT_PressY Decimal Gesture recognition;...
  • Page 46: Ubt_Backlight Container Diagram

    Saia-Burgess Controls AG 7.5.5 uBT_BackLight container diagram 7.5.6 Additional uBTerminal containers for "Save logs to File" function Name of the contai- Default Meaning Access uBT_TrendPath Dynamically linked file path Only readable uBT_TrendDevice INFLASH: Energy saving facility Only readable uBT_TrendDir WEBPAGES/ Subdirectory for saving all trends.
  • Page 47: List Of Message Box Messages

    Saia-Burgess Controls AG List of message box messages Messages Remarks Can be shown if a file (usually a .gif) is too big. VGA MB Panel: < 256 kB Out of memory in Ramdisk (see also Section 18) Language Failed to parse .csv No available memory for parsing a .csv file LR: out of memory! or out of No available memory for parsing a .csv file.
  • Page 48: Handling: Precautionary Measures

    Saia-Burgess Controls AG ReadFile on remote host has Regular polling of the PPO failed. failed! Communication buffer OVF in Spider_fileReadln()! When loading the file, more data were received than the buffer can hold. Range is null! Area of a bar chart was calculated incorrectly. value out of range! The min./max.
  • Page 49 Saia-Burgess Controls AG Abrasive cleaners and/or cleaning equipment that could damage or scratch the surface of the MB Panel must not be used! Used denatured alcohol and apply it with a clean, soft cloth. At the end, wash off the alcohol using plain water and a clean, soft cloth (recommended) When cleaning, ensure that no liquids can get inside the panel.
  • Page 50: General Recommendations Regarding The Web Editor

    (PLC or local MB Panel server) under INFLASH/webpages/.  Adding Unicode fonts  For more information visit: http://www.sbc-support.com  Product Info  HMI  PCD7.D4xxx Web Panel  If the correct font type is not in the list please contact PCD Support in Murten. We would be happy to help.
  • Page 51: A Number Of Rules Relating To Gif Images

    Saia-Burgess Controls AG A number of rules relating to gif images  The three times given in the display of the MB Panel are: o Repaint from the video cache o Decompress to the video cache in the event of a URL jump and after starting (virtually linear with number of pixels).
  • Page 52: Decompressing Gif Files To The Video Cache When Starting Using A Dummy Start Page

    Saia-Burgess Controls AG - For control in LOG.TXT (UBT_FS/LOG.TXT) 9.4.2 Decompressing gif files to the video cache when starting using a dummy start page Give all gifs in a teq start page that serves as a placeholder. → This solution allows you to decompress the gif files to the video cache before the real page for the project is displayed.
  • Page 53: Advanced Error Messages For The Panel

    Saia-Burgess Controls AG Advanced error messages for the panel More information: The following messages * can be displayed if the amount of memory required by the gif files, paint- ers, html tags, container variables, online/offline trends, HD logs and language resources (.csv files) is too large.
  • Page 54: A Appendix

    Saia-Burgess Controls AG Appendix Icons This symbol indicates further information available in this or another manual or in technical documents relating to this topic. No direct refer- ences are made to such documents. This symbol indicates instructions which must be followed. Saia-Burgess address Saia-Burgess Controls AG Bahnhofstrasse 18...