Container Variable
(source HN)
uBT_EnableSIP
uBT_FirstPadName
uBT_BuzzVol
uBT_BuzzFreqIndex
uBT_AlarmStart **
uBT_AlarmFrequency
**
uBT_AlarmVolume **
* Parameter access over FTP using the configuration file in INTFLASH, INFLASH/
CONFIG/CONFIG.DAT.
The settings can be read over a file read of this file over FTP.
Overwriting the file over FTP causes the terminal to take all changes that are
given within the file.
Manual PCD7.D4xx │  D ocument 26-851 ENG12  │   2 016-02-05
FTP
Description
Config
option
R/W
Read/Write SIP→Select Soft Input Panel (keyboard on the
screen)
Write 0→SIP is disabled. Virtual keyboards are disabled.
Write 1→SIP is enabled. Virtual keyboards (alphapad.teq
and keypad.teq) are enabled.
R/W
File name entry for an alternative virtual keyboard file as
replacement for alphapad.teq at local file use.
At local file use alphapad.teq from the setup menu (from
INTFLASH/WEB) is used by default.
The alternative file–that must be named otherwise than
alphapad.teq–can be placed in M1 or SD flash over FTP, or
included in the stored web project in the remote server.
The maximum number of characters (file extension with dot
included) is 24.
R/W
Read/Write buzzer volume setting (0...20).
This sets the volume of the acoustic signal at the use of the
touch function of the touch panel.
As pulse width modulation is used to control the volume
this setting has an influence on the sensed pitch of the
alarm.
Volume 0 setting switches it off.
R/W
Read/write buzzer frequency selection (0...6).
This equals to 125, 250, 500, 1000, 2000, 4000, 8000 Hz
setting.
This sets the pitch of the acoustic signal at the use of the
touch function of the touch panel.
no
Write a value to start or stop the pulsed acoustic alarm.
The acoustic alarm can be started with a setting of the
interval time (0...30000 ms) of the pulsed signal. (30000 =
30 s)
A 50% duty cycle is used with pulse time equal to pause
time.
If already running a renewed setting is ignored.
Setting it to 0 however switches it off immediately.
The alarm also stops by any touch on the screen.
R/W
Frequency setting of the acoustic alarm (Hz)
(Rounded down to 125, 250, 500, 1000, 2000, 4000, 8000)
Use this before starting the alarm.
Renewed setting during running alarm will be first used at
the next start of the alarm.
R/W
Acoustic alarm volume setting (value 0...20) 20 = 100%
As pulse width modulation is used to control the volume
this setting has an influence on the sensed pitch of the
alarm.
Use this before starting the alarm.
Renewed setting during running alarm will be first used at
the next start of the alarm.
Update & special settings
Special internal Functions
6
6-15