COmmISSIONING
Transport, Installation, Commissioning
G300.2 G320.2 (turning length 1400 mm) zero series
DIE235EN - 2022-12-05

Pressure accumulator

If the machine was shipped by plane, all accumulators attached to the machine are
depressurized.
Before start-up of the machine, all accumulators must be filled with nitrogen (N
by a specialist. The prescribed pressures must be observed.
For the prescribed pressures, see the hydraulic diagrams in Chapter 2, "Diagrams
and drawings".

Data loss due to prolonged downtime

The machine is functional only after all data have been entered.
After a prolonged downtime of the machine, data may be lost in the RAM.
In such a case, the lost data must be re-entered or re-loaded before the machine
can be put back into operation.
The data are recorded in the start-up report and backed up on a storage medium.
The start-up report and the storage medium are located in the document pocket in
the door of the control cabinet.

Switching on the machine

See document "Operating the Machine".
)