INSTAllATION
fluidic system
Transport, Installation, Commissioning
G300.2 G320.2 (turning length 1400 mm) zero series
DIE235EN - 2022-12-05
Fluidic system
The cooling system, lubrication system, and hydraulic system are located on the left
front/rear side of the machine.
Coolant tank (X), lubricating oil tank (Y), and hydraulic fluid tank (Z) were not emp-
tied before transport.
Fill only the coolant indicated on the coolant tank (X) at the filler neck
(X1).
The filler neck has a ventilation opening.
Fill in only the lubricating oil type indicated on the lubricating oil tank
(Y) at the filler neck (Y1).
The filler neck has a ventilation opening.
Fill in only the fluid type indicated on the hydraulic fluid tank (Z) at
the filler neck (Z1).
The filler neck has a ventilation opening.
For the appropriate types of lubricating oil, hydraulic fluid, grease, and cooling
lubricant, see the Chapter 1, "Information on operating materials" and "Hydraulic
diagrams and machine installation plan" in Chapter 2, "Diagrams and drawings".
Z1
Z
DIE140ZZ_14.tif
Y
X
X1
Y1