12. LED Lamp

■ Do not connect or disconnect the motor connectors while the power to the robot
system is turned ON. Connecting or disconnecting the motor connectors with
the power ON is extremely hazardous and may result in serious bodily injury as
the Manipulator may move abnormally, and also may result in electric shock
and/or malfunction of the robot system.
■ To shut off power to the robot system, disconnect the power plug from the power
source. Be sure to connect the AC power cable to a power receptacle.
WARNING
DO NOT connect it directly to a factory power source.
■ Before performing any replacement procedure, turn OFF the Controller and
related equipment, and then disconnect the power plug from the power source.
Performing any replacement procedure with the power ON is extremely hazardous
and may result in electric shock and/or malfunction of the robot system.
Maintenance
LED Lamp
parts
Cross-point screwdriver
Tools
Nippers
Wire tie
Material
(1) Remove the Arm Top Cover.
LED Lamp
For details, refer to 3.1 Arm Top Cover.
Removal
(2) Remove the User Plate.
For details, refer to 3.5 User Plate.
(3) LS3-B:
LS6-B:
(4) Turn the lens counterclockwise to remove.
Then, turn the lens holder counterclockwise
to remove.
(5) Remove the LED and ring from the User
Plate.
LS-B series Maintenance Rev.1
Name
Disconnect the connector from LED.
Connector: X22
Disconnect the X1 and X2 terminals from
the LED.
LS3-B LS6-B Maintenance 12. LED Lamp
Qty.
LS3-B: 2198273
1
LS6-B: 2077258
1
For wire removal
1
1
X2 Terminal
(LS6-B)
Note
Lens
Lens Holder
Ring
LED
X1 Terminal
(LS6-B)
Connector: X22
(LS3-B)
97