LS3-B LS6-B Maintenance 12. LED Lamp
LED Lamp
(1) LS3-B:
Installation
LS6-B:
(2) Put the User Plate between the ring and lens holder, and then secure the LED to the
cover.
(3) Mount the lens.
(4) Mount the User Plate.
For details, refer to 3.5 User Plate.
(5) Install the Arm Top Cover.
For details, refer to 3.1 Arm Top Cover.
98
Connect the connector to LED.
Connector: X22
Connect the X1 and X2 terminals to the LED.
Each terminal must be connected to the same terminal number on the LED.