3.5 Connector Sub Plate

■ Do not remove the connector sub plate forcibly. Removing the connector sub
plate forcibly may result in damage to the cables, disconnection, and/or contact
failure.
hazardous and may result in electric shock and/or improper function of the robot
system.
■ When mounting the connector sub plate, be careful not to allow the cables to
interfere with the plate mounting and do not bend these cables forcibly to push
them into the cover.
CAUTION
Unnecessary strain on cables may result in damage to the cables, disconnection,
and/or contact failure.
extremely hazardous and may result in electric shock and/or improper function of
the robot system.
When routing the cables, observe the cable locations after removing the connector
sub plate. Be sure to place the cables back to their original locations.
Unscrew the Connector Sub Plate
mounting bolts and remove the
plate.
LS-B series Maintenance Rev.1
Damaged cables, disconnection, or contact failure is extremely
Refer to
LS-B series Manual – LS20-B
Manipulator 3.6 Connecting the
Cables.
Damaged cables, disconnection, or contact failure is
LS20-B Maintenance 3. Covers
4-M3×10
Finger Screws
(No need to unscrew)
Connector
Sub Plate