Displaying the measured value status
If the Analog Input, Digital Input and Totalizer function blocks are configured for cyclic
data transmission, the device status is coded as per PROFIBUS Profile Specification 3.02
and transmitted along with the measured value to the PROFIBUS Master (Class 1) via the
coding byte (byte 5). The coding byte is split into three segments: Quality, Quality
Substatus and Limits.
Quality
 17
Structure of the coding byte
The content of the coding byte depends on the configured failsafe mode in the particular
function block. Depending on which failsafe mode has been configured, status information
in accordance with PROFIBUS Profile Specification 3.02 is transmitted to the PROFIBUS
Master (Class 1) via the coding byte.
Determining the measured value status and device status via the diagnostic behavior
When the diagnostic behavior is assigned, this also changes the measured value status and
device status for the diagnostic information. The measured value status and device status
depend on the choice of diagnostic behavior and the group in which the diagnostic
information is located. The measured value status and device status are firmly assigned to
the particular diagnostic behavior and cannot be changed individually.
The diagnostic information is grouped as follows:
• Diagnostic information pertaining to the sensor: diagnostic number 000 to 199
→  91
• Diagnostic information pertaining to the electronics: diagnostic number 200 to 399
→  92
• Diagnostic information pertaining to the configuration: diagnostic number 400 to 599
→  92
• Diagnostic information pertaining to the process: diagnostic number 800 to 999
→  92
Depending on the group in which diagnostic information is located, the following
measured value status and device status are firmly assigned to the particular diagnostic
behavior:
Diagnostic information pertaining to the sensor (diagnostic no.: 000 to 199)
Diagnostic behavior
(configurable)
Quality
Alarm
BAD
Warning
GOOD
Measuring value
Quality Substatus
Measured value status (fixed assignment)
Quality
Coding
Substatus
(hex)
Maintenance
0x24 to 0x27
alarm
Maintenance
0xA8 to 0xAB
demanded
Diagnostics and troubleshooting
Coding
(hex)
Byte 5
Limits
Device diagnostics
Category
(fixed assignment)
(NE107)
F
Maintenance
(Failure)
alarm
M
Maintenance
(Maintenance)
demanded
A0021271-EN
91