Endress+Hauser Proline Cubemass C 100 PROFIBUS DP Operating Instructions Manual page 48

Coriolis flowmeter
Hide thumbs Also See for Proline Cubemass C 100 PROFIBUS DP:
Table of Contents

Advertisement

Operation options
48
Typical functions:
• Configuring parameters of transmitters
• Loading and saving device data (upload/download)
• Documentation of the measuring point
• Visualization of the measured value memory (line recorder) and event logbook
For additional information about FieldCare, see Operating Instructions BA00027S
and BA00059S
Source for device description files
See information →  50
Establishing a connection
1. Start FieldCare and launch the project.
2. In the network: Add a device.
 The Add device window opens.
3. Select the CDI Communication TCP/IP option from the list and press OK to confirm.
4. Right-click CDI Communication TCP/IP and select the Add device option in the
context menu that opens.
5. Select the desired device from the list and press OK to confirm.
 The CDI Communication TCP/IP (Configuration) window opens.
6. Enter the device address in the IP address field and press Enter to confirm:
192.168.1.212 (factory setting); if the IP address is not known .
7. Establish the online connection to the device.
For additional information, see Operating Instructions BA00027S and BA00059S