X500-X505 Drive-Cliq Interfaces; X524 Electronics Power Supply - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.3.2.2

X500-X505 DRIVE-CLiQ interfaces

Table 7-2
Connector
type
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 x) Article No.: 6SL3066-4CA00-0AA0
Note
Only MOTION-CONNECT DRIVE-CLiQ cables may be used to establish connections.
The maximum length of MOTION-CONNECT 500 is 100 m and for MOTION-CONNECT 800PLUS
cables, 75 m.
7.3.2.3

X524 Electronics power supply

Table 7-3
Type: Spring-loaded terminal 6 (Page 320)
The maximum cable length is 30 m.
Note
The two "+" and/or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
X500-X505: DRIVE-CLiQ interfaces
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
DRIVE-CLiQ socket
X524: Electronics power supply
Terminal Designation
+
Electronics power supply (24 V)
+
Electronics power supply (24 V)
M
Electronics ground (0 V)
M
Electronics ground (0 V)
7.3 DRIVE-CLiQ Hub Module DMC20
Technical data
Transmit data +
Transmit data -
Receive data +
-
-
Receive data -
-
-
Power supply
Electronics ground
Technical data
Voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption: Max. 2.4 A
(including DRIVE-CLiQ)
Max. current via the jumper in the con‐
nector: 20 A (15 A according to UL/CSA)
Hub Modules
201

Advertisement

Table of Contents
loading

This manual is also suitable for:

6sl3055-0aa00-5ea

Table of Contents