9.8.4
Dimension drawing
111,7 (4.40)
Figure 9-30
Dimension drawing of the Sensor Module External SME20, all data in mm and (inches)
9.8.5
Installation
5,3 (0.21)
①
Contact surface
Figure 9-31
Drilling pattern for installing the SME20/SME25
Installation
1. Place the drilling pattern on the mounting surface. Make sure that the contact surface is bare,
unpainted metal.
2. Drill two holes with Ø 5.3 or M5 threaded holes according to the drilling pattern.
3. Fix the Sensor Module to the mounting surface. The tightening torque is 6 Nm (53.1 lbf in).
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
80 (3.14)
50 (1.97)
9.8 Sensor Module External SME20
SME20: 12 poles
SME25: 17 poles
without cable lug
General tolerance ± 0.5 (± 0.02)
50 (1.97)
10 (0.39)
Ø5,3 (0.21)
M5 / 6 Nm
20 (0.79)
Encoder system connection
32 (1.26)
58 (2.27)
Ø5,3 (0.21)
M5 / 6 Nm
1
10 (0.39)
20 (0.79)
279