X500-X505 Drive-Cliq Interfaces; X524 Electronics Power Supply - Siemens SINAMICS S120 Combi Manual

Power modules
Hide thumbs Also See for SINAMICS S120 Combi:
Table of Contents

Advertisement

Additional system components
9.2 DRIVE-CLiQ Hub Module DMC20
9.2.3.2

X500-X505 DRIVE-CLiQ interfaces

Table 9- 16
Connector type
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 x) Article No.: 6SL3066-4CA00-0AA0
Note
Only MOTION-CONNECT DRIVE-CLiQ cables may be used to establish connections.
The maximum length of MOTION-CONNECT 500 is 100 m and for MOTION-CONNECT
800PLUS cables, 75 m.
9.2.3.3

X524 Electronics power supply

Table 9- 17
Type: Screw terminal 3 (Page 288)
The maximum cable length that can be connected is 30 m.
Note
The two "+" and "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE-CLiQ participants.
212
X500-X505: DRIVE-CLiQ interfaces
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
DRIVE-CLiQ socket
X524: Electronics power supply
Terminal
Designation
+
Electronics power supply
+
Electronics power supply
M
Electronics ground
M
Electronics ground
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Technical specifications
Voltage: 24 VDC (20.4 ... 28.8 V)
Current consumption: Maximum 0.5 A
Maximum current through the jumper in the
connector: 20 A (15 A according to UL/CSA)
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7

Advertisement

Table of Contents
loading