Where UL-compliant design is not required, use of the following cables and connectors from
Siemens is recommended:
Pre-assembled cables
Connecting cable for power supply with M12 plug and M12 socket,
A-coded, 4-pin,
Article number: 6XV1801-5D..
Cables to be assembled by the user
Cable
24 V DC cable,
2-wire, 2 x 0.75 mm
Article number: 6XV1812-8A
Table 7-8
Connected
loads
Cross-section
0.34 mm²
2 x 0.34 mm²
0.75 mm²
2 x 0.75 mm²
T
= 55 °C
a
100 m DRIVE-CLiQ
Connected motors with DRIVE-CLiQ encoder, DRIVE CLiQ mounted encoder SME
1)
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
,
2
Cable length P24 supply cable
1
1)
m
75 m
100 m
100 m
100 m
7.4 DRIVE-CLiQ Hub Module External DME20
Connector
M12 plug connector,
4-pin, A-coded,
Article number: 6GK1907-0DC10-6AA3
2
3
45 m
30 m
90 m
65 m
100 m
75 m
100 m
100 m
Hub Modules
4
5
25 m
20 m
50 m
40 m
60 m
50 m
100 m
100 m