Technical Data - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Terminal Modules
6.3 Terminal Module TM15
6.3.9

Technical data

Table 6-9
Technical data
6SL3055-0AA00-3FA.
Electronics power supply
Voltage
Current (without DRIVE-CLiQ or digital outputs)
Power loss
Max. cable length
I/O
Digital inputs/outputs
Number of digital inputs/outputs
Electrical isolation
Max. cable length
Digital inputs
Voltage
Low-level (an open digital input is interpreted as
"low")
High level
Input Impedance
Input current, typical (at 24 V DC)
Max. voltage in the off state
Current in OFF state
Typical input delay of the digital inputs
Digital outputs (continued-short-circuit-proof)
Voltage
Max. load current per digital output
Output delay (resistive load)
Typical
Maximum
Min. output pulse
(100% amplitude, 0.5 A with ohmic load)
Switching frequency
For resistive load
For inductive load
For lamp load
Maximum lamp load
Max. switching frequency
(100% amplitude, 50%/50% duty cycle;
with 0.5 A and an ohmic load)
Voltage drop in ON state
Leakage current in OFF state
128
Unit
V
DC
A
DC
W
m
Can either be parameterized as DI or DO
24
Yes, in groups of 8
m
V
DC
V
DC
V
DC
mA
V
DC
mA
μs
V
DC
A
DC
μs
μs
μs
Hz
Hz
Hz
W
kHz
V
DC
μA
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Value
24 (20.4 ... 28.8)
≤0.15
≤3
30
30
-30 ... +30
-30 ... +5
15 ... 30
2.8
9
5
0.0 ... 1.0 (per channel)
"0" → "1": 50
"1" → "0": 100
24
0.5
"0" → "1": 50
"1" → "0": 150
"0" → "1": 100
"1" → "0": 225
125 (typ.)
350 (max.)
Max. 100
Max. 0.5
Max. 10
5
1 (typ.)
0.75 (max.) for maximum load in all cir‐
cuits
Max. 10 per channel
Control Units and additional system components

Advertisement

Table of Contents
loading

This manual is also suitable for:

6sl3055-0aa00-5ea

Table of Contents