X522 Bidirectional Digital Inputs/Outputs; X524 Electronics Power Supply - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

6.3.2.5

X522 bidirectional digital inputs/outputs

Table 6-6
Type: Screw terminal 1 (Page 321)
L3+: The 24 V DC infeed for DI/DO 16 to 23 (third potential group) must always be connected if at least
1)
one DI/DO of the potential group is used as an output.
M3: The ground reference for DI/DO 16 to 23 (third potential group) must always be connected if at
least one DI/DO of the potential group is used as an input or output.
DI/DO: Bidirectional digital input/output
6.3.2.6

X524 Electronics power supply

Table 6-7
Type: Spring-loaded terminal 6 (Page 320)
The maximum cable length is 30 m.
Note
The two "+" and "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The digital outputs are supplied via terminals X520, X521, and X522.
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
X522 digital inputs/outputs
Terminal
1
1
2
3
4
5
6
7
8
9
10
10
X524 electronics power supply
Terminal Designation
+
Electronics power supply (24 V)
+
Electronics power supply (24 V)
M
Electronics ground (0 V)
M
Electronics ground (0 V)
Designation
Technical data
1)
L3+
See Chapter "Technical data
(Page 128)".
DI/DO 16
DI/DO 17
DI/DO 18
DI/DO 19
DI/DO 20
DI/DO 21
DI/DO 22
DI/DO 23
M3 (GND)
Technical data
Voltage: 24 V DC (20.4 ... 28.8 V)
Current consumption: max. 0.6 A
(including DRIVE-CLiQ and control of dig‐
ital outputs)
Max. current via the jumper in the con‐
nector: 20 A (15 A according to UL/CSA)