X524 Electronics power supply

Table 9- 16
Terminals for the electronics power supply
Terminal
+
+
M
M
Max. connectable cross-section: 2.5 mm
Type: Screw terminal 3 (see Chapter "Control cabinet installation and EMC / connection system")
Note
The two "+" and "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.
The current consumption increases by the value for the DRIVE-CLiQ participants.
9.2.3.3

X500 - X505 DRIVE-CLiQ interfaces

Table 9- 17
DRIVE-CLiQ interfaces X500 - X505
Pin
1
2
3
4
5
6
7
8
A
B
Connector type: RJ45 socket
DRIVE-CLiQ port rubber plug included in the scope of delivery;
rubber plug (50 pieces) Order number: 6SL3066-4CA00-0AA0
Note
Only MOTION-CONNECT DRIVE-CLiQ cables may be used to establish connections.
The maximum length of MOTION-CONNECT 500 cables is 100 m and of MOTION-
CONNECT 800 cables 50 m.
SINAMICS S120 Combi
Manual, Edition 05.2010, 6SL3097-4AV00-0BP0
Designation
Electronics power supply
Electronics power supply
Electronics ground
Electronics ground
2
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
9.2 DRIVE-CLiQ Hub Module DMC20
Technical specifications
Voltage: 24 V DC (20.4 V – 28.8 V)
Current consumption: Max. 0.5 A
Max. current via jumper in connector: 20 A
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply