Limiting the tilt angle

1. With a 7/64'' Allen key, loosen screws
A, located on locking collars B.
2. Position the locking collars B at the
desired location on both cylinder
rods C to limit tilt.
3. Tighten screws A firmly.

Replacing the self-blocking cylinder

The following steps explain how to replace the self-blocking cylinder. It is important to
follow these steps in the order indicated.
1. Make sure the seat is parallel to the
ground (see section Adjusting the tilt
angle) to improve safety during
cylinder replacement.
2. Unfasten and remove the cylinder
cable.
3. With a 4mm wrench, unfasten and
remove screws A.
4. With a 4mm Allen key and a 10mm
wrench, unfasten shoulder screw B.
5. With a 4mm Allen key, unfasten
screws C.
6. With a 19mm wrench, unfasten the
cylinder end D from the old cylinder
and install on the replacement
cylinder.
7. With a 4mm Allen key, fasten screws
C.
8.
With a 4mm Allen key and a 10mm
wrench, fasten shoulder screw B.
With a 4mm wrench, fasten screws A.
9.
Note - Make sure that all hardware is
properly reinstalled and that
each screw is firmly tightened.
10.
Fasten the cylinder cable to the new
self-blocking cylinder.