[Record Settings]
The alarm settings allow you to capture images before and/or after the motion or I/O event
happens.
Pre-alarm recording time: Activates video recording before an event occurs. Set the
recording time to 1 or 2 seconds. The recording is saved in the buffer of the camera.
Post-alarm recording time: Activates video recording onto the inserted memory card
after an event occurs. Set the recording time from 1 to 30 seconds.
Split Interval (Max. Video Clip): Sets the maximum time length of each recorded file
from 1 to 5 minutes.
Record Profile: This setting is only applicable for recording to the camera's memory card.
Select Performance to maximize the lifespan of the memory card by restricting the
maximum bit rate to 4 Mbit and Sharpness value to 30. Select Quality to adopt your
current settings.
Record Audio: Activates audio recording when an event occurs.
Write recording data into local storage: Select to continue recording to the local
storage while live view is being accessed through Web interface or other applications
such as GV-System / GV-VMS. This option is enabled by default.
Note: To optimize recording results, it is recommended to allow no more than two
connections to the camera using Web interface or any other applications when Write
recording data into local storage is enabled.
[Text Overlay Settings] Displays camera name, date, and/or time on the live view and
recorded videos when viewing through GeoVision software.
Camera Name: Type the camera name.
Overlay with: Select one or more of the options below to be overlaid on the live view and
recorded videos.
Camera Name
Date
System Time
Name of the Associated Digital Input: This function is only supported by GV-
FE2301 / 4301 and GV-FER12203.
86