Lenovo 5458 Installation And Service Manual page 417

Table of Contents

Advertisement

Severity: Error
User response: Complete the following steps:
If system failed to boot successfully, DC cycle
1.
system.
If system boots to F1 steup, flash UEFI image and
2.
reset bank to primary (if required). If system boots
without error, recovery is complete and no
additional action is required.
If system fails to boot, or if flash attempt fails,
3.
(trained service technician only) replace the system
board.
S.51003
[S.51003] An uncorrectable memory error
was detected in DIMM slot % on rank
%.
Explanation: Fatal Memory Error Occurred
Severity: Error
User response: Complete the following steps:
1.
If the node has recently been installed, moved,
serviced, or upgraded, verify that the DIMM is
properly seated and visually verify that there is no
foreign material in any DIMM connector on that
memory channel. If either of these conditions is
found, correct and retry with the same DIMM.
(Note: Event Log may contain a recent 00580A4
event denoting detected change in DIMM
population that could be related to this problem.)
2.
If no problem is observed on the DIMM connectors
or the problem persists, replace the DIMM
identified by LightPath and/or event log entry.
3.
If problem re-occurs on the same DIMM connector,
replace the other DIMMs on the same memory
channel.
4.
Check IBM Support website for an applicable
service bulletin or firmware update that applies to
this memory error.
(Trained service technician only) If problem
5.
re-occurs on the same DIMM connector, inspect
connector for damage. If found, replace system
board.
(Trained service technician only) Replace affected
6.
Processor.
(Trained service technician only) Replace system
7.
board.
S.51006
[S.51006] A memory mismatch has been
detected. Please verify that the memory
configuration is valid.
Explanation: One or More Mismatched DIMMs
Detected
Severity: Error
User response: Complete the following steps:
1.
Could follow an uncorrectable memory error or
failed memory test. Check log and service that
event first. DIMMs disabled by other errors or
actions could cause this event.
2.
Verify that the DIMMs are installed in the correct
population sequence, according to the service
information for this product.
3.
Disable memory mirroring and sparing. If this
action eliminates the mismatch, check IBM Support
website for information related to this problem.
4.
Reflash UEFI firmware.
5.
Replace DIMM
6.
(Trained service technician only) Replace Processor.
S.51009
[S.51009] No system memory has been
detected.
Explanation: No Memory Detected
Severity: Error
User response: Complete the following steps:
1.
Make sure that one or more DIMMs are installed in
the server.
2.
If no memory fault is recorded in the logs and no
DIMM connector error LEDs are lit, verify that all
DIMM connectors are enabled using the Setup
utility or the Advanced Settings Utility (ASU).
3.
Re-Install all DIMMs verifying the correct
population sequence, according to the service
information for this product.
4.
(Trained service technician only) Replace the
processor.
5.
(Trained service technician only) Replace the
system board.
S.58008
[S.58008] A DIMM has failed the POST
memory test.
Explanation: DIMM Failed Memory Test
Severity: Error
User response: Complete the following steps:
1.
You must AC-cycle the system to re-enable affected
DIMM connector or re-enable manually using F1
setup
2.
If the node has been recently installed, serviced,
moved, or upgraded, check to ensure that DIMMs
are firmly seated and that no foreign material can
be seen in the DIMM connector. If either condition
is observed, correct and retry with the same DIMM.
(Note: Event Log may contain a recent 00580A4
event denoting detected change in DIMM
population that could be related to this problem.)
If problem persists, replace the DIMM identified by
3.
LightPath and/or event log entry.
If problem re-occurs on the same DIMM connector,
4.
swap the other DIMMs on the same memory
Appendix B. UEFI (POST) error codes
S.51003 • S.58008
401

Advertisement

Table of Contents
loading

Table of Contents