80010701-0701ffff • 80010701-2701ffff
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010701-0701ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(PCI Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Non-critical
sensor going high has asserted.
May also be shown as 800107010701ffff or
0x800107010701ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
2.
Check the server airflow. Make sure that nothing is
blocking the air from coming into or preventing the
air from exiting the server.
80010701-0702ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(VRD Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Non-critical
sensor going high has asserted.
May also be shown as 800107010702ffff or
0x800107010702ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
328
System x3250 M5 Type 5458: Installation and Service Guide
2.
Check the server airflow. Make sure that nothing is
blocking the air from coming into or preventing the
air from exiting the server.
80010701-0703ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(Ambient 1 Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Non-critical
sensor going high has asserted.
May also be shown as 800107010703ffff or
0x800107010703ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
2.
Check the server airflow. Make sure that nothing is
blocking the air from coming into or preventing the
air from exiting the server.
80010701-2701ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(Ambient 2 Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Non-critical
sensor going high has asserted.
May also be shown as 800107012701ffff or
0x800107012701ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
Check the server airflow. Make sure that nothing is
2.
blocking the air from coming into or preventing the
air from exiting the server.