80070614-2201ffff • 806f0007-0301ffff
http://www-03.ibm.com/systems/bladecenter/
resources/powerconfig.html.
2.
Follow actions in "Power Problems and Solving
Power Problems".
If the specified sensor is PS n 12V OV Fault, complete
the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
(Trained technician only) Replace the system board.
(n = power supply number)
If the specified sensor is PS n 12V UV Fault, complete
the following steps until the problem is solved:
Check power supply n LED.
1.
Remove the failing power supply.
2.
3.
Follow actions in "Power Problems and Solving
Power Problems".
4.
(Trained technician only) Replace the system board.
(n = power supply number)
If the specified sensor is PS n 12Vaux Fault, complete
the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Replace power supply n. (n = power supply
number)
80070614-2201ffff
Sensor [SensorElementName] has
transitioned to non-recoverable. (TPM
Phy Pres Set)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
non-recoverable.
May also be shown as 800706142201ffff or
0x800706142201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 50
Automatically notify Support: No
User response:
Update the server firmware (see Recovering the
1.
server firmware).
If the problem persists, (trained technician only)
2.
replace the system board (see Removing the system
board and Installing the system board).
336
System x3250 M5 Type 5458: Installation and Service Guide
80080128-2101ffff
Device
[LogicalDeviceElementName] has been
added. (Low Security Jmp)
Explanation: This message is for the use case when an
implementation has detected a Device was inserted.
May also be shown as 800801282101ffff or
0x800801282101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0536
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
800b0108-1301ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Power Unit)
Explanation: This message is for the use case when
Redundancy Lost has asserted.
May also be shown as 800b01081301ffff or
0x800b01081301ffff
Severity: Error
Alert Category: Critical - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 9
Automatically notify Support: No
User response:
1.
Check the LEDs for both power supplies.
2.
Follow the actions in Power-supply LEDs.
806f0007-0301ffff
[ProcessorElementName] has
Failed with IERR. (CPU 1)
Explanation: This message is for the use case when an
implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070301ffff or
0x806f00070301ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0042
SNMP Trap ID: 40
Automatically notify Support: No

Advertisement