1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a
5.
lit status LED.
806f060d-0403ffff
Array
[ComputerSystemElementName] has
failed. (Drive 3)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0403ffff or
0x806f060d0403ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0404ffff
Array
[ComputerSystemElementName] has
failed. (Drive 4)
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0404ffff or
0x806f060d0404ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
806f060d-0403ffff • 806f060d-0406ffff
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a
5.
lit status LED.
806f060d-0405ffff
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0405ffff or
0x806f060d0405ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Replace the RAID adapter.
5.
Replace the hard disk drive that is indicated by a
lit status LED.
806f060d-0406ffff
Explanation: This message is for the use case when an
implementation has detected that an Array Failed.
May also be shown as 806f060d0406ffff or
0x806f060d0406ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0176
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
Appendix A. Integrated Management Module II (IMM2) error messages
Array
[ComputerSystemElementName] has
failed. (Drive 5)
Array
[ComputerSystemElementName] has
failed. (Drive 6)
361